Orbit Merret OMM 37 Manual

3 1/2 digit dc voltmeter/ammermeter process monitor thermometer for pt 100
Hide thumbs Also See for OMM 37:

Advertisement

GUARANTEE
Y
E
A
R
S
OMM 37
3 1/2 DIGIT
DC VOLTMETER/AMMERMETER
PROCESS MONITOR
THERMOMETER FOR Pt 100

Advertisement

loading

Summary of Contents for Orbit Merret OMM 37

  • Page 1 GUARANTEE OMM 37 3 1/2 DIGIT DC VOLTMETER/AMMERMETER PROCESS MONITOR THERMOMETER FOR Pt 100...
  • Page 2 For safety information the EN 61 010-1 + A2 standard must be observed. This instrument is not explosion-safe! TECHNICAL DATA Measuring instruments of the OMM 37 series conform to the European regulation 89/336/EWG and the Ordinance 168/1997 Coll. They are up to the following European and Czech standards:...
  • Page 3 Certificate of guarantee ................11 INSTRUCTIONS FOR USE OMM 37...
  • Page 4: Instrument Description

    INSTRUMENT DESCRIPTION Description The OMM 37 model series include simple 3 1/2 digit panel instruments in these alternatives: DC voltmeter/ammeter Process monitor Thermometer for Pt 100 sensors For their dimensions the instruments are suitable for mosaic panel installation. ADJUSTABLE DISPLAY PROJECTION Setting by potentiometers from the back of the instrument (in the range of approx.
  • Page 5: Connection

    Provided this cannot be secured it is necessary to use shielded leads with connection to ground. The instruments are tested in compliance with standards for use in industrial area, yet we recommend to abide by the above mentioned principles. OM 37DC, PM OM 37RTD INSTRUCTIONS FOR USE OMM 37...
  • Page 6: Setting

    (approx. ±10 %) Full range Offset shifting zero (compensation of 2-wire lead for OMM 37RTD), the trimmer is fitted only in the OMM 37PM and RTD model Full range Offset Brightness regulation INSTRUCTIONS FOR USE OMM 37...
  • Page 7 INSTRUMENT SETTING INSTRUCTIONS FOR USE OMM 37...
  • Page 8: Technical Data

    10x (t < 100 ms), 2x (long-term) Calibration: at 23°C and 40 % r.h. POWER SUPPLY 7…12 V AC/DC, max. 100 mA 10…30 V AC/DC, max. 160 mA (DC), 280 mA (AC), (24 VDC/55 mA), isolated INSTRUCTIONS FOR USE OMM 37...
  • Page 9 7. TECHNICKÁ DATA TECHNICAL DATA INSTRUCTIONS FOR USE OMM 37...
  • Page 10 INSTRUMENT DIMENSIONS Front view Panel cut 48 mm 43,5 mm Side view 72 mm 5 mm Panel thickness: 0,5...20 mm INSTRUCTIONS FOR USE OMM 37...
  • Page 11 - other unprofessional interference nprofessional interference The manufacturer performs guarantee and post-guarantee repairs unless provided for otherwise. ms guarantee and post-gua st-guarantee repairs unless provided for otherwise. e repairs unless provided for otherwis Stamp, signature INSTRUCTIONS FOR USE OMM 37...
  • Page 12 NOTE TECHDOK - OMM 37 - 2009 - 6v1 - en - V INSTRUCTIONS FOR USE OMM 37...