Abus SHRM10000 Original Operating Instructions

Abus SHRM10000 Original Operating Instructions

Z-wave smoke detector
Hide thumbs Also See for SHRM10000:

Advertisement

Quick Links

SHRM10000
ABUS Z-Wave Smoke detector
Important information and FAQs about this product and other
products can be found on the website
www.abus.com
Version 1.0
Original operating instructions in English.
Keep for future use!
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SHRM10000 and is the answer not in the manual?

Questions and answers

Summary of Contents for Abus SHRM10000

  • Page 1 SHRM10000 ABUS Z-Wave Smoke detector Important information and FAQs about this product and other products can be found on the website www.abus.com Version 1.0 Original operating instructions in English. Keep for future use!
  • Page 2: Table Of Contents

    English Summary Introduction ............................3 1.1. Declaration of Conformity ......................3 1.2. Declaration of Service ......................3 1.3. Disclaimer of Liability ....................... 3 Important Safety Informations ......................4 2.1. Intended Use ........................... 4 2.2. Unboxing ..........................4 2.3. Installation location / operating environment ................4 2.4.
  • Page 3: Introduction

    Your rights are limited to the repair or replacement of this product as delivered. ABUS Security Center assumes no liability for any special, incidental or consequential...
  • Page 4: Important Safety Informations

    ABUS Security Center is limited to the purchase price of the product.
  • Page 5: Information On Handling Batteries

    English 2.5. Information on handling batteries Make sure that batteries are kept away from small children. Children may put batteries in their mouths and swallow them. This can cause serious harm to their health. If this happens, consult a doctor immediately. Do not charge normal batteries, heat them up or throw them into naked flames (they may explode).
  • Page 6: Information On Device Disposal

    Separate collection and recycling saves natural resources and ensures that all the provisions for protecting health and environment are observed when recycling the product. 3. Product introduction 3.1. Scope of delivery ABUS Z-Wave Smoke detector Quickguide & Safety Instructions Installation material 3.2. Device features...
  • Page 7: Funktionsprinzip

    3.3. Funktionsprinzip The SHRM10000 was developed for use in home automation systems that use the Z- Wave wireless standard. The detector alarms loudly thanks to the integrated siren (> 85dB). When the battery level is low, the detector automatically gives feedback to the gateway.
  • Page 8: Special Installation Cases

    English Smoke alarm devices are to be used as the bare minimum equipment in all bedrooms, children's rooms and hallways which act as escape routes, and are to be installed in each case in the middle of the room, on the ceiling only (do not install on a wall) (Fig.
  • Page 9: Where Smoke Alarm Devices Should Not Be Installed

    English Mezzanines and landings  In the case of mezzanines and landings with a length and width of > 2 m and a total area of > 16 m², an additional smoke alarm should be installed in the centre of the surface area.
  • Page 10: Normal State

    English  In rooms in which the alarm could be triggered by disturbance variables (steam, condensation, “normal” smoke, vapour, dust, dirt or grease)  Next to an air duct or similar ventilation opening (draughts)  In areas in which the temperature can fall below 0°C or rise to over 40°C 4.2.
  • Page 11: Alarm State: Smoke

    English 4.6. Alarm state: Smoke If smoke is detected, a loud, pulsing alarm tone sounds and the red LED flashes at the same time at short intervals. In this case, proceed as described in the “Behaviour in case of alarm” chapter. 4.7.
  • Page 12: Mounting & Installation

    English Press the Network-button 3 times within 1.5 seconds and the Status-LED on the base unit front will flash 3 times The App will show if the Add device process was successful and the Status-LED will turn Repeat the inclusion process from step B if it was not successful.
  • Page 13: Exclusion / Remove Device

    English Check the functionality of the smoke alarm device by pressing the Test button. The warning tone signals and the red “ALARM” LED flashes quickly This does not indicate that smoke is present in the air in the room; it is a confirmation that the smoke alarm device is functioning properly.
  • Page 14: Reset (Factory-Reset)

    English 5.4. Reset (Factory-Reset) 1. Remove the battery 2. Press the Network button and keep it pressed while inserting the battery again. Device will restore factory settings Note: 1, This procedure should only be used if the primary gateway is not capable of acting. 2, If the multi-sensor is set to the factory setting, the status is set to "not included", the association...
  • Page 15: Supported Command Classes

    Powerlevel Version 1 Battery Version 1 Security 2 Version 1 Supervision Version 1 Wake Up Version 2 7. Technical Specifications Parameters Unit SHRM10000 Dimensions 60 x 60 x 49,2 Weight 0 – 40 Operating Temperature °C Max. Humidity IP Class...
  • Page 16 English Power consumption standby 0,01 Power consumption trigger Battery-life 5 Jahre (1 trigger per month + 1 heartbeat per day + 1 active report per day) Range (open field) Range (building) 20, related to material of walls Tamper protection Firmware updateable Support Z-Wave Beaming SmartStart supported Z-Wave Network Security...