STANDARD FLUE HORIZONTAL
0100
MAX 686 mm Ax 1
MIN 250 mm Ax 1*
0125
MAX 1070 mm Ax 1
MIN 250 mm Ax 1*
* Requires cutting
MAXIMUM FLUE HORIZONTAL
0100- 7goo mm
Ax1+Bx8
0125- 18500 mm
Ax1+Bx18
MAXIMUM FLUE VERTICAL START+ 1 BEND
0
c
0100- 7goo mm
Ax1+Cx1+Bxg
+
Fx
1
0125- 18500 mm
Ax1+Cx1+Bx1g
+
Fx 1
MAXIMUM FLUE HORIZONTAL+ 1 BEND
bJ)
0
'-----_' - --ll<CI
I
P
A
B
0
c
0100- 5goo mm
Ax1 + Bx7+Cx1
0125- 16500 mm
Ax1 + Bx17+Cx1
FLUE OPTIONS 30CDi
CONVENTIONAL
MAXIMUM FLUE VERTICAL
START+ 2 BENDS
F
8
d
I
IPA
B
~---~
co
0100- 5goo mm
Ax1+Cx2+ Bx8
+
Fx 1
0125- 16500 mm
A
X
1 +
c
X
2 + B
X
18
+
Fx
1
MAXIMUM FLUE VERTICAL
START+ 3 BENDS
F
B
c
0
0100- 3goo mm
Ax1+Cx3
+Bx7+Fx1
0125- 14500 mm
Ax1+Cx3
+Bx17+Fx1
MAXIMUM FLUE VERTICAL
WITH 2 X 45° BENDS
E
B
D
0100- 7400 mm
(including terminal)
Bx8+Dx2+Ex1
0125- 16500 mm
(including terminal)
Bx17+ Dx2 +Ex1
VERTICAL FLUE WITH
2 X goo BENDS
E
B
c
0
0100-5400 mm
(including terminal)
Bx7+ Cx2 +Ex1
0125- 14500 mm
(including terminal)
Bx16+ Cx2 +Ex1
6 720 611 927-08.10
FLUE OPTIONS 30CDi
CONVENTIONAL
•
The diagrams (opposite) show the compo-
nents used and the maximum flue length for
each configuration of 100 mm and
125 mm 0 flues.
•
Shaded flue components indicate the stan-
dard 100 mm 0 horizontal flue.
•
Only straight flue sections can be reduced
in length and cut.
•
The flue terminal end can be fitted from the
inside or outside of the building.
Fixing kits are supplied with the flue exten-
sion kits.
Horizontal125 mm 0 and Vertical100 mm
and 125 mm 0 flue kits are available with
separate instructions. Contact your supplier
or Worcester Bosch.
A
c
D
QH
iP
0
v
B
EB
F
Q
A - Standard horizontal flue (1 00 mm 0 shown)
B - Straight flue extension
C - Flue bend, goo
D - Flue bends, 45°
E - Vertical terminal (vertical adaptor supplied
with terminal)
F- Vertical adaptor (used with horizontal
terminal)
Calculating the flue length:
Measure the total flue length required, noting
that the maximum straight flue length including
the terminal is:
Horizontal 60/100 mm 0: 7goo mm
Horizontal 80/125 mm 0: 18500 mm
Vertical 60/100 mm 0: g400 mm
Vertical 80/125 mm 0: 18500 mm
Then reduce the total straight flue length for
each extra flue bend (excluding the turret) by:
2000 mm for goo
1000 mm for 45°
Flue extension total lengths:
Horizontal & Vertical 60/100 mm 0: g5o mm
Horizontal & Vertical 80/125 mm 0: 1000 mm
Flue terminal total lengths:
Horizontal 60/100 mm 0: 800 mm
Horizontal 80/125 mm 0: 1200 mm
Vertical60/100 mm 0: 1140 mm
Vertical 80/125 mm 0: 1365 mm
INSTALLATION & SERVICING INSTRUCTIONS
FOR
WORCESTER
BOSCH GREENSTAR
30CDI/40CDI Coc,ectlocal
~ORCESTER
6
720
614
556a
(2007/07)
Bosch Group