Locking The Keypad - Realistic HTX-202 Manual

Hide thumbs Also See for HTX-202:
Table of Contents

Advertisement

2. Select the desired frequency.
3. If + or - is on the display, repeatedly press F & + / - until neither
symbol appears.
4. Press LOW POWER so that the button is down. In this position, your
transceiver transmits at about 1 watt.
5. Begin communications.
If the other party advises that you need to improve your signal (QRO),
press LOW POWER so that the button is up. In this position, your
transceiver transmits at the highest power it can, depending on the power
source. Remember to switch back to low power whenever possible, to
comply
with the FCC rules that require you to use the minimum power necessary to
maintain communications.
Follow these steps to communicate using duplex communications.
1. Turn on the transceiver.
2. Tune to the desired receive (output) frequency.
3. If the transmit (input) frequency is 600 kHz ABOVE the receive
frequency, press F+ +/- so that the + appears in the display. If the
transmit frequency is 600 kHz BELOW the receive frequency, press F+ +/-
so that - appears on the display. If the frequency separation is not
600 kHz, either set a new default frequency or store the frequency pair
in one of the scanner's memories (See "Using Memory Channels" and
"Setting the Duplex Separation").

LOCKING THE KEYPAD

To lock the transceiver's keypad so that you do not accidently change a
setting, press F+LOCK. LOCK appears on the display. This locks all front-
panel buttons and the tune control. The PTT, VOLUME, and SQUELCH still
operate. To release the lock, press F+LOCK again.