Floor Protection (Corner Installation)
A combustible floor must be protected by non-combustible
material (like tile, concrete board, or certified to UL-1618 or
as defined by local codes) extending beneath the heater and
a minimum of 8" (203mm) from each side and minimum 16"
(406mm)** from the front face of the stove and minimum 6"
(152mm)** (or the rear clearance to combustibles whichever
is smaller) from the rear of the stove.
When installed with horizontal venting, non-combustible floor
protection must beneath the flue pipe and extend 2" (51mm)
beyond each side.
Minimum Overall Width (X) of Floor
Protector for all installations:
Stove
F2500M
Minimum Overall Depth (Y) of Floor Protector
Unit
Medium F2500M
Canada - 49" (1245mm)
USA -
Minimum Overall Depth (Y) of Floor Protector - Corner Hearth
Reference only when hearth pad is installed to rear wall at minimum pipe clearances.
Hearth Depth
F2500
L
Residential Installation ''C'' Vent (Single Wall)
Canada
33-11/16" (856mm)
USA
33-11/16" (856mm)
Residential Close Clearance (To be installed with required pipe components)
Canada
33-11/16" (856mm)
USA
33-11/16" (856mm)
M
L
F2500 Regency Freestanding Woodstove
for angled corners
33-11/16" (856 mm)
Residential
"C" Vent
Y
Z
**6" (152mm)
47" (1194mm)
M
N
61-7/16" (1561mm)
51-1/8" (1299mm)
59-7/16" (1510mm)
49-3/4" (1264mm)
57-15/16" (1472mm)
48-5/8" (1235mm)
55-15/16" (1421mm)
47-1/4" (1200mm)
N
O
X
16"
Y
**NOTE: In Canada, floor protection must extend 18" (450mm) to
the front and 8" (203mm) to back of the stove.
From Edge of Fuel Door
Opening
W
8" (203mm)
O
27-5/16" (694mm)
25-7/8" (657mm)
24-13/16" (630mm)
23-7/16" (595mm)
W
Z
W
installation