Connection With Separate Pipes; Service And Maintenance - Ferroli SKY ECO F Series Instructions For Use, Installation & Maintenance

Hide thumbs Also See for SKY ECO F Series:
Table of Contents

Advertisement

SKY ECO F
For the coaxial connection, install one of the following
initial accessories on the unit. For drilling dimensions on
the wall, see section 4.1. Horizontal exhaust segments
must slope slightly toward the outside to prevent any
condensation from returning to the unit.
Initial accessories for coaxial ducts
C
5x
Example of a connection with separate pipes
C1x Horizontal aspiration and evacuation on the wall.
Intake and exhaust terminals must be concentric,
or close enough to be exposed to similar wind
conditions (maximum distance of 50 cm).
C3x
Intake/exhaust terminals suitable for C12.
C5x Separate aspiration and evacuation on the wall
or ceiling or, in any case, in areas under different
pressure. Aspiration and evacuation may not be
placed on opposite walls.
C6x
Aspiration from the installation environment and
evacuation on the wall or ceiling.
= Air
= Flue gases
B
C
2x
1x
cod. 3541S170 - Rev. 00 - 02/2019
IMPORTANT - THE ROOM MUST
To connect the separate ducts, install the following initial
accessory on the unit (010031X0 / 4740).
Table 2
Model
SKY ECO F 11
Maximum permit-
SKY ECO F 14 55 m
ted length
SKY ECO F 17 45 m
SKY ECO F 11
Diaphragm to be
SKY ECO F 14
used
SKY ECO F 17

3 SERVICE AND MAINTENANCE

eq
eq
eq
0 - 20 m
Ø 40
eq
20 - 35 m
Ø 43
eq
no diaphragm
eq
0 - 20 m
Ø 47
eq
20 - 35 m
Ø 50
eq
20 - 55 m
no diaphragm
eq
0 - 20 m
Ø 50
eq
20 - 35 m
Ø 52
eq
20 - 45 m
no diaphragm
eq
EN
-
-
-
-
73

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sky eco f 11Sky eco f 14Sky eco f 17

Table of Contents