Quick Menu

The QUICK MENU key gives access to 41 of
the most important setup parameters of the
drive. After programming, the drive will, in many
cases, be ready for operation.
Quick Menu
Parameter
Number
number
1
102
2
103
3
104
4
105
5
106
6
201
7
202
8
206
9
207
10
415
11
413
12
414
13
227
14
228
15
204
16
205
17
700
18
701
19
702
20
703
21
704
22
705
23
706
24
707
25
708
26
709
27
710
28
711
29
712
30
713
31
714
32
418
33
419
34
719
35
720
36
721
37
420
38
422
39
427
40
423
41
424
VLT Type
Ramp up time
(par.206)
7002-7011
1 sec.
7016-7062
3 sec.
7072
5 sec.
46
Name
Units
Motor Power
KW/HP
Motor Voltage
Volt
Motor Frequency
Hz
Motor Current
Amps
Rated motor speed
RPM
Min. Frequency
Hz
Max. Frequency
Hz
Ramp up time
seconds
Ramp down time
Seconds
Pressure unit
Minimum Feedback
Par. 415
Maximum Feedback
Par. 415
Warning Low Feedback
Par. 415
Warning High Feedback
Par. 415
Minimum reference
Par. 415
Maximum reference
Par. 415
Cascade mode
Pump Combination
Staging bandwidth
%
SBW destage delay
Sec.
SBW stage delay
Sec.
Override bandwidth
%
Override timer
Sec.
Destage by timer
Sec.
Staging frequency
%
Destaging frequency
%
Delay before running on mains
ms
Sleep/AUX timer
Sec.
Sleep/AUX frequency
Hz
Wakeup/disable AUX -
Hz
frequency
Boost setpoint
%
Setpoint 1 (H0)
Par. 415
Setpoint 2 (H1)
Par. 415
Pump enable
Indexed par.
Pump running hours
Hours
Setpoints
Par. 415
Normal/inverse control
PID start up frequency
Hz
PID Lowpass filter time
Sec.
PID Proportional Gain
Factor
PID Integrator time
Sec.
Ramp down time
(par.207)
1 sec.
2 sec.
3 sec.
VLT® 7000 Booster
Range
1,1-55/1,5-75
380-460
50/60 Hz
0-Ivlt,max
1200 - f m,n x 60
0,0 - fmax
fmin - 120/1000
1-60
1-60
999.999,999-FBmax
FBmin - 999.999,999
999.999,999-FBhigh
FBlow - 999.999,999
Min. feedback - Max. reference
Min. reference - Max. feedback
1-14
0-100
0-3000
0-3000
0-100 (100=Off)
0-300
0-301 (301=Off)
0-100% of f
max
0-100% of f
max
0-2000
0-300 (301 = Off)
Par. 201 - Par. 713
Par. 712 - Par. 202
1-200% of Setpoint 1
Par. 413-Par. 414
Par. 413-Par. 414
0-1
0,0-999.999,9
0,0-999.999,9
Normal/inverse
f
- f
min
max
0.01-10.00
0.00-10.00
0.01-9999.00
1) Depending on Mode, please refer to par. 700.
2) Depending on Mode, with AUX pump: 150
sec., without AUX pump: OFF.
MG.70.A1.02 - VLT is a registered Danfoss trademark
Factory Setting
kW
50 Hz
-
-
20 Hz
50 Hz
See table below
See table below
Bar
0.000
100.000
-999.999.999
999.999.999
0.000
50.000
1
1
DOM
5
10
10
Off
10
Off
90
50
500
2
DOM
20 Hz
50 Hz
100%
0.000
0.000
1
-
-
Normal
0
0.2
0.3
Off