Siemens SITRANS P310 with HART Compact Operating Instructions page 41

Pressure transmitter
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
Certificates and approvals
Designation
Connection "nA"
Connection "ic"
Effective inner capacitance
Effective inner inductance
Explosion protection in accordance
with FM
Designation (XP/DIP) or IS; NI; S
Permissible ambient temperature
Explosion protection as per CSA
Designation (XP/DIP) or (IS)
Permissible ambient temperature
A
Appendix
A.1
Certificate
The certificates can be found on the enclosed CD and on the Internet under:
Certificates (http://www.siemens.com/processinstrumentation/certificates)
A.2
Technical support
Technical Support
If this documentation does not provide complete answers to any technical questions you may have, contact Technical
Support at:
● Support request (http://www.siemens.com/automation/support-request)
● More information about our Technical Support is available at
Technical support (http://www.siemens.com/automation/csi/service)
Internet Service & Support
In addition to our documentation, Siemens provides a comprehensive support solution at:
● Service&Support (http://www.siemens.com/automation/service&support) where you will find support news, support
documents including EDDs and software, and also support from experts.
40
HART
II 2/3 G Ex nA IIC T4/T5/T6 Gc
II 2/3 G Ex ic IIC T4/T5/T6 Gc
U
= 45 V
n
To a circuit with the operating values:
U
= 45 V
i
C
= 6 nF
i
L
= 0.4 mH
i
Certificate of Compliance 3008490
CL I, DIV 1, GP ABCD T4 ... T6; CL II, DIV 1, GP EFG; CL III; CL I, ZN 0/1 AEx ia
IIC T4 ... T6; CL I, DIV 2, GP ABCD T4 ... T6; CL II, DIV 2, GP FG; CL III
T
= T4: -40 ... +85 °C (-40 ... +185 °F)
amb
T
= T5: -40 ... +70 °C (-40 ... +158 °F)
amb
T
= T6: -40 ... +60 °C (-40 ... +140 °F)
amb
Certificate of Compliance 1153651
CL I, DIV 1, GP ABCD T4 ... T6; CL II, DIV 1, GP EFG; CL III; Ex ia IIC T4 ... T6:
CL I, DIV 2, GP ABCD T4 ... T6; CL II, DIV 2, GP FG; CL III
T
= T4: -40 ... +85 °C (-40 ... +185 °F)
amb
T
= T5: -40 ... +70 °C (-40 ... +158 °F)
amb
T
= T6: -40 ... +60 °C (-40 ... +140 °F)
amb
SITRANS P310 with HART
A5E35075329-01, 05/2015

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents