Wiring and Termination
Typical Wiring Table
Cable
Electri
Con
Series
cal De
struc
sign
tion
1.6mm
cable
with 2
con
3-Wire
TH53-
duc
(Source
MTQG
tors, 2
Follow
shield
er)
wires
and
shield
1.6mm
cable
with 2
con
2-Wire
TH53-
duc
(Com
LEMO
tors, 2
mon
shield
Source)
wires
and
shield
1.6mm
cable
with 2
con
2-Wire
TH53-
duc
(Com
NC
tors, 2
mon
shield
Source)
wires
and
shield
Re
place
Polari
For Use
ment
ty
With
Con
nector
Posi
tive
with
All Shure
re
WA430
TA4F Body
spect
packs
to
ground
Shure Lemo
bodypacks
(ADX1-
Nega
Lemo, Shure
tive
UR1M-
with
Lemo,
re
WA416
ULXD1-
spect
Lemo),
to
Sennheiser
ground
SK5212,
Lectrosonics
SSM, and
others
LEMO:
WA416,
Nega
Shure
tive
TQG/
with
TA4F:
Termination
re
WA430,
Dependent
spect
Lec
to
troson
ground
ics
TA5F:
WA435
Wiring
Line Art (From Solder Side)
Red wire: Bias(2)
Blue wire: Audio(3)
Shield wire: Ground(1)
Shield: Ground (Shell)
Red wire: Audio/
Bias(3)
Blue wire: Not con
nected
Shield wire: Ground(1)
Red wire: Audio/Bias
Blue wire: Not con
nected
Shield wire: Ground
Shield: Ground (Shell)
Shure Incorporated
11/17