Operation Manual – OAM
H3C S3610&S5510 Series Ethernet Switches
Errored-frame-period Event threshold
Errored-frame-seconds Event period
Errored-frame-seconds Event threshold :
2)
Configure Device B:
# Configure Ethernet 1/0/1 to operate in active OAM mode (the default OAM mode) and
enable OAM for it.
<DeviceB> system-view
[DeviceB] interface ethernet 1/0/1
[DeviceB-Ethernet1/0/1] oam enable
[DeviceB-Ethernet1/0/1] quit
# Display OAM link error event statistics.
[DeviceB] display oam link-event remote
Port :Ethernet1/0/1
Link Status :Up
OAMRemoteErrFrameEvent : (ms = milliseconds)
---------------------------------------------------------------------
Event Time Stamp
Errored Frame Threshold
Error Running Total
The above information indicates that 35 errors occurred since OAM is enabled on
Device A, 17 of which are caused by error frames. The link is instable.
:
1
:
60
1
: 5789
Errored FrameWindow
: 1
Errored Frame
: 35
Event Running Total
1-10
Chapter 1 OAM Configuration
: 10(100ms)
: 3
: 17