Bit 0: Host/Local (R/W)
0 = Local
1 = Host
Bit 1: Run/Stop (R/W)
0 = stop
1 = Run
Bit 2: Load/Unload (R/W)
0 = Unload
1 = Load
Bit 3: Modulating (R)
0 = Not Modulating
1 = Modulating
Bit 4: Unused
Bit 5: Stopped in Auto Restart (R)
0 = Not Stopped in Auto Restart
1 = Stopped in Auto Restart
FIGURE 4-2 INTELLISYS SSR CONTROLLER REGISTER OISTATUSICONTROL
Register 096: Language
0 = English
1 = Spanish
2 = French
3 = Portuguese
Register 99: Rated Horse Power
0 = 50
1 =60
2 = 75
FIGURE 4-3 INTELLISYS SSR CONTROLLER REGISTER CODES
Bit 0: Run/Stop (R)
0 = stop
1 = Run
Bit 1: On/Off Line Mode (R)
0 = Not in On/Off Line Mode
1 = On/Off Line Mode
Bit 2:. MODlACS Mode (R)
0 = Not in Mod/ACS Mode
1 = Mod/ACS Mode
Bit 3: Load/Unload (R)
0 = Unload
FIGURE 4-4 INTELLISYS SSR CONTROLLER STATUS ALARM HISTORY
16
Bit 6: Alarm (R)
0 = No Alarms
1 = Alarms
Bit 7: Warning (R)
0 = No Warnings
Bit 8: On/Off Line Mode (R)
0 = Not in On/Off Line Mode
1 = On/Off Line Mode
Bit 9: Mod/ACS or Mod Only (R)
0 = Not in Mod/ASC Mode
1 = Mod/ASC Mode
Bits 10-12: Unused
Bits 13-15: Unit Type (R)
001 = SSR controller
Register 097: Units of Measure
0 = " F and PSI
1 = " C and PSI
2 = " C and Bar
3 = " C and kPa
4 = " C and kg/cm2
6 = 200
7 = 250
8 = 300
9 = 350
Bit 4: Stopped Auto Restart (R)
0 = Not Stopped in Auto Restart
1 = Stopped in Auto Restart
Bit 5: Unused
Bit 6: Unused
Bit 7: Unused