Fault Finding The Product; Disposing Of The Product - Grundfos UNOLIFT Series Installation And Operating Instructions Manual

Table of Contents

Advertisement

12. Fault finding the product

WARNING
Biological hazard
Death or serious personal injury
- Wear protective gloves, close the
isolating valves and drain the tank
before you start any work on the tank.
Fault
1.
The pump does
not start.
2.
The pump does
not stop.
3.
The pump starts
and stops
randomly.
4.
The tank is not
emptying although
the pump is
running.
5.
The pump makes
an unusual sound.

13. Disposing of the product

This product or parts of it must be disposed of in an
environmentally sound way:
1. Use the public or private waste collection service.
2. If this is not possible, contact the nearest
Grundfos company or service workshop.
Cause
a)
The float switch is blocked in low
position.
b)
The pump cable is defective.
a)
The float switch is blocked in high
position.
a)
The float switch is not set properly.
b)
The level sensor tube is not fixed
properly in the tank and is moving up
as the liquid rises. The sensor receives
wrong signals.
c)
The float switch cannot move freely
because the pump has moved.
a)
There is an airlock in the pump
impeller. The pump cannot build up
pressure.
a)
The pump is blocked.
For faults indicated by alarms and related to the
controller, see the installation and operating
instructions of the controller.
For faults related to the pumps, see the installation
and operating instructions of the pumps.
Remedy
1. Make sure that the float switch can
move freely.
2. It may be necessary to adjust the
cable length. See section
7.1 Setting the start
Repair or replace the cable.
1. Make sure that the float switch can
move freely.
2. It may be necessary to adjust the
cable length. See section
7.1 Setting the start
Adjust the cable length of the float
switch. See section
start
levels.
Fix the tube to the tank. See fig. 13.
Position the pump according to fig.
or 10.
Drill a hole of maximum 6 mm in the
connecting pipes in the tank. The air is
pushed out when the pump starts, and
the pump builds up pressure. The
pressure loss due to the hole is
negligible.
Do not drill a hole in the outlet pipe
outside the tank.
Take the pump out of the tank and
remove the blockage. You may need
to dismantle the pump. See the
installation and operating instructions
of the pump.
The crossed-out wheelie bin symbol on
a product means that it must be
disposed of separately from household
waste. When a product marked with this
symbol reaches its end of life, take it to a
collection point designated by the local
waste disposal authorities. The separate collection
and recycling of such products will help protect the
environment and human health.
levels.
levels.
7.1 Setting the
9
21

Advertisement

Table of Contents
loading

Table of Contents