  • Page 1 ® Operating & Installation Instructions...
  • Page 3: Table Of Contents

    C O N T E N T S QUICK GUIDE OPERATING INSTRUCTIONS FUEL LIGHTING CONTROLLING THE FIRE REFUELLING ASH CLEARANCE REDUCED BURNING MAINTENANCE THROAT PLATE AND FLUEWAY CLEANING CHIMNEY SWEEPING TROUBLE SHOOTING CO ALARM IF YOU NEED FURTHER HELP UNPACKING THE STOVE HEALTH AND SAFETY PRECAUTIONS CO ALARMS SPECIFICATION...
  • Page 4: Quick Guide

    High Output Output SERVICING Stove should be serviced by a professional at least once a year. LIGHTING AND CONTROLLING THE FIRE Suitable fuels for your Charnwood: Wood logs Unsuitable fuels: Petroleum coke Liquid fuel Household waste Coal singles Add kindling and paper or...
  • Page 5: Operating Instructions

    OPERATING INSTRUCTIONS ® Congratulations on becoming the owner of a Charnwood Aire 5 Approximate suitable log sizes are: Stove. Your stove has been approved in smoke control areas to burn 300mm(11in) long and 75mm (3in) diameter wood logs if it is used in accordance with these instructions. It is very important that you read and understand these instructions before Log moisture content of less than 20% is recommended.
  • Page 6: Refuelling

    1cm thick on the base of the ashpan. Before removing ash The Charnwood Aire 5 is fitted with an air control stop for use in a ensure that it has cooled down. The ashpan slides out for easy ash smoke control area.
  • Page 7: Throat Plate And Flueway Cleaning

    Repairs or modifications may plate (see Fig. 2 ). only be carried out by the Manufacturer or their approved agents. Use only genuine Charnwood replacement parts. Different types of sweep’s brushes are available to suit different flueways. For prefabricated insulated chimneys the manufacturers THROAT PLATE AND FLUEWAY CLEANING instructions with regard to sweeping should be consulted.
  • Page 8: Trouble Shooting

    When the chimney is warm a draught reading of at least 1.25 mm (0.05 in.) water gauge (12Pa) should be obtained. Some blackening If you need further help with your Charnwood then your Installer of the glass may occur below the level of the fuel retainer. This will will be able to provide the answers to most questions.
  • Page 9: Unpacking The Stove

    The External air supply kits are available please contact Charnwood for wrapping is first removed, then the stove released from the pallet by more information. Instruction sheet ref: TIS 120 removing 4 pallet bolts using a 10mm spanner.
  • Page 10: Chimney

    This may be stainless steel, cast iron, or thick wall steel pipe. but is not suitable for using for the complete chimney. If it is found Charnwood Pipe to match the stove is available if required. that there is excessive draw in the chimney then a draught stabiliser The flue spigot can be shieled with starter length flue see fig.
  • Page 11: Soot Doors

    INSTALLATION INSTRUCTIONS ® The stove comes with the blanking plate (fig. 9) fitted to the top Fig. 5 Vertical Register Plate With Bricked Up Fireplace flue outlet. The seal for the top outlet is a 155mm dia ring of rope Soot door inside or rear of chimney seal.
  • Page 12 INSTALLATION INSTRUCTIONS ® and you can contact them for details of Clean Air Act requirements. Fig. 8 Horizontal Register Plate With Optional Vertical Rear Flue Connector Alternative soot door positions The Aire 5 has been been recommended as suitable for use in smoke control areas when burning wood logs.
  • Page 13: Dimensions

    DIMENSIONS ® VERTICAL REAR FLUE ADAPTOR To suit 150mm PLAN VIEW (6”) flue pipe WITH HEATSHIELD FRONT SIDE REAR...
  • Page 14: Aire 5 Store Stand Parts List

    Charnwood Aire 5 Store Stand Parts List AIRE 5 STORE STAND PARTS LIST Issue A ® Item Part No. Description Item Part No. Description 008/AB035 Rope Door Seal 010/AB130 Air Control Plate 008/FW29 Door Seal Adhesive 004/AB115 Slider 006/AB018 Glass (Inc Seal)
  • Page 15: Aire 5 Low Parts List

    Charnwood Aire 5 Low Stand Parts List AIRE 5 LOW PARTS LIST Issue A ® Item Part No. Description Item Part No. Description 008/AB035 Rope Door Seal 008/AB110 Air Control Gasket 008/FW29 Door Seal Adhesive 010/AB130 Air Control Plate 006/AB018...
  • Page 16: Certific Ation

    CERTIFIC ATION ® ® AJ WELLS & SONS LTD Bishops Way, Newport, Isle Of Wight PO30 5WS, United Kingdom A Division of A.J.Wells & Sons Limited Registered In England No. 03809371 CE certificate for compliance with EN13240:2001 EN13240:2001 ROOMHEATERS FIRED BY SOLID FUEL AIRE 5 STORE STAND AIRE 5 LOW Model:...
  • Page 17 ErP (EU 2015/1187) EN - PRODUCT FICHE IT - SCHEDA PRODOTTO FR - FICHE DE PRODUIT PL - KARTA PRODUKTU MANUFACTURER MARQUE MARCHIO Bishops Way, Newport, Isle of Wight PO30 5WS, United Kingdom MARCA A Division of A.J.Wells & Sons Limited Registered in England No. 03809371 MODEL MODÈLE MODELLO...
  • Page 20 your premier dealer...

This manual is also suitable for:

Aire 5 store standAire 5 low

Table of Contents