ABB ACS800 Firmware Manual page 282

Crane control program
Hide thumbs Also See for ACS800:
Table of Contents

Advertisement

282
WARNING
CAUSE
FAST STOP
Fast Stop Signal
(FFF8)
FLWR1 LIM/FLT
Follower 1 has gone into a fault or has hit any
of the limits. This message is displayed in the
(FFFD)
Master drive only
FLWR2 LIM/FLT
Follower 2 has gone into a fault or has hit any
of the limits. This message is displayed in the
(FFFE)
Master drive only
FLWR3 LIM/FLT
Follower 3 has gone into a fault or has hit any
of the limits. This message is displayed in the
(FFB5)
Master drive only
FLWR4 LIM/FLT
Follower 4 has gone into a fault or has hit any
of the limits. This message is displayed in the
(FFB4)
Master drive only
HW RECONF RQ
Inverter type (for example, sr0025_3) has been
changed. Inverter type is usually changed at
(FF38)
factory or during drive implementation.
HIGHEND LIMIT
High-end limit Signal
direction
(FFF6)
HOMING ACTIVE
Homing activation signal
EXT 1 control
(FFB1)
HOMING DONE
Homing sequence is completed in EXT 1
control. The position is initialized to the value
(FFB0)
define in par
LOWEND LIMIT
Low-end limit Signal
down direction
(FFF7)
ID DONE
Drive has performed motor identification
magnetisation and is ready for operation. This
(FF32)
warning belongs to normal start-up procedure.
ID MAGN
Motor identification magnetisation is on. This
warning belongs to normal start-up procedure.
(FF31)
ID MAGN REQ
Motor identification is required. This warning
belongs to normal start-up procedure. The
(FF30)
drive expects you to select how motor
identification should be performed: With
identification magnetisation or with ID Run.
ID N CHANGED
Drive ID number has been changed from 1.
(FF68)
ID RUN
Motor identification run is on.
(FF35)
Fault tracing
10.10
activated.
10.12
activated in the Up
10.21
activated in
78.10.
10.13
activated in the
WHAT TO DO
Deactivate the Fast Stop signal.
See Follower 1 drive for more detailed
description of fault of limit.
See Follower 2 drive for more detailed
description of fault of limit.
See Follower 3 drive for more detailed
description of fault of limit.
See Follower 4 drive for more detailed
description of fault of limit.
Wait until alarm POWEROFF! activates and
switch control board power off to validate
inverter type change.
Run the motor in the opposite direction and
deactivate the High-end limit signal.
Homing sequence is activated. Start the drive
and complete the homing sequence. After
homing sequence is done deactivate the
homing active signal.
Homing sequence is completed. Deactivate
the homing active signal and continue
operation.
Run the motor in the opposite direction and
deactivate the Low-end limit signal.
Continue drive operation.
Wait until drive indicates that motor
identification is completed.
Start identification magnetisation by pressing
Start key, or select ID run and start (see
parameter 99.10).
Change ID number back to 1. See chapter
Control
panel.