Actual Signals - ABB ACS800 Firmware Manual

Crane control program
Hide thumbs Also See for ACS800:
Table of Contents

Advertisement

156
No.
Name/Value

04 ACTUAL SIGNALS

04.01
FAULTED INT INFO
04.02
INT SC INFO
09 ACTUAL SIGNALS
09.01
AI1 SCALED
09.02
AI2 SCALED
09.03
AI3 SCALED
09.04
AI5 SCALED
09.05
AI6 SCALED
09.06
DS MCW
09.07
MASTER REF1
09.08
MASTER REF2
09.09
AUX DS VAL1
09.10
AUX DS VAL2
09.11
AUX DS VAL3
09.12
AUX DS VAL4
09.13
AUX DS VAL5
09.14
AUX DS VAL6
09.15
LCU ACT SIGNAL1
09.16
LCU ACT SIGNAL2
1) Percent of motor maximum speed / nominal torque / maximum process reference (depending on the
ACS800 macro selected).
2) The contents of these data words are detailed in chapter
Actual signals and parameters
Description
Signals for the Adaptive Program
A 16-bit data word. See section
Fieldbus
control.
A 16-bit data word. See section
control.
Signals for the Adaptive Program
Value of analogue input AI1 scaled to an integer value.
Value of analogue input AI2 scaled to an integer value.
Value of analogue input AI3 scaled to an integer value.
Value of analogue input AI5 scaled to an integer value.
Value of analogue input AI6 scaled to an integer value.
Control Word (CW) of the Main Reference data set received from the
Master station through the fieldbus interface
Reference 1 (REF1) of the Main Reference data set received from the
Master station through the fieldbus interface
Reference 2 (REF2) of the Main Reference data set received from the
Master station through the fieldbus interface
Auxiliary data set value 1 received from the Master station through the
fieldbus interface
Auxiliary data set value 2 received from the Master station through the
fieldbus interface
Auxiliary data set value 3 received from the Master station through the
fieldbus interface
Auxiliary data set value 4 received from the Master station through the
fieldbus interface
Auxiliary data set value 5 received from the Master station through the
fieldbus interface
Auxiliary data set value 6 received from the Master station through the
fieldbus interface
Line-side converter signal selected with parameter
SEL. A 16-bit data word.
Line-side converter signal selected with parameter
SEL. A 16-bit data word.
03.37 FCW WITH POS
in chapter
04.02 INT SC INFO
in chapter
95.08
LCU PAR1
95.09
LCU PAR2
Fieldbus
control.
FbEq
2)
Fieldbus
20000 = 10 V
20000 = 20
mA
20000 = 20
mA
20000 = 20
mA
20000 = 20
mA
0 ... 65535
(Decimal)
-32768 ...
32767
-32768 ...
32767
-32768 ...
32767
-32768 ...
32767
-32768 ...
32767
-32768 ...
32767
-32768 ...
32767
-32768 ...
32767