From the Power screen, you can control and monitor the
following functions:
• Inverter Power: Use the toggle button to turn the
inverter on or off. The Operating Mode indicator
displays the operating mode of the inverter:
– Battery mode indicates that the inverter is running
and supplying AC power to the loads from battery.
– Grid mode indicates that the inverter is charging the
battery with AC voltage from shore power, but it's
bypassing the inverter supply of AC power to the
loads directly from the shore power.
– Off appears when the inverter is either off, or it is in
an error, fault, or warning state.
If the inverter is in an error, fault, or warning state,
I
the error code will be indicated on the inverter
LCD screen.
• Battery: These indicators provide voltage readings for
the chassis (engine) and house (coach) batteries,
respectively.
• Load Wattage: This indicator displays the power
consumed by the load from the inverter when in
battery mode.
• Charger Stage: This indicator shows the charger
status of the onboard charger, as described in the
following table:
Number Status
Description
0
Disabled
The charger is disabled.
1
Not
The charger is enabled, but it is not
Charging
charging (typically due to a lack of
AC power).
2
Bulk
The charger is in the initial stage of
the three-stage charging cycle.
3
Absorption The charger is in the second stage of
the three-stage charging cycle.
4
Over
The charger is over-charging the bat-
Charge
teries (this status is rare).
5
Equalize
The charger is equalizing the
batteries.
6
Float
The charger is in the third stage of
the three-stage charging cycle.
7
Constant
The charger is providing constant
Voltage
voltage charging (typically used
during single-stage charging cycles).
EN
• Charger Current: This indicator shows the current
that the charger is drawing from shore power.
• AC Input Current: This indicator shows the input
current being drawn from shore power.
• AC Load Current: This indicator shows the current
that the loads are drawing directly from shore power,
bypassing the inverter.
• Generator: These options control both input and
output, so you can monitor and control the onboard
generator:
– The hours indicator shows the number of hours that
the generator has run.
– The status indicator shows the state of the
generator, as described in the following table:
Number Status
0
Stopped
1
Pre-Heat
2
Cranking
3
Running
4
Priming
5
Fault
6
Engine Run Only
7
Test Mode
8
Voltage-Adjust-Mode This status is unused.
9
Fault-Bypass-Mode
10
Configuration-Mode This status is unused.
For a complete list of generator statuses, refer to
I
the RV-C Specifications PDF.
Operation
Description
The generator is stopped.
The generator is preheat-
ing. This is done prior to
the cranking cycle.
The generator is starting.
The generator is running.
The generator is advanc-
ing fuel.
There is a fault.
The generator is running,
but not producing AC
power.
This status is unused.
This status is unused.