OETIKER FAST 3000 Safety light curtain
6.2

Verifying the closing force

NOTE
To check the correct operation of the force load cell, verify the measured force at least once a week, using an
Oetiker CAL 01.
If the force is set to 1850 N, the force measured by the OETIKER CAL 01 must be within a tolerance of ± 100 N of
that value.
The tensioning strap should be replaced after about 50 verifications.
Setting with CAL 01: SKS mode: hold-ME-EL / average (see user manual OETIKER FAST 3000)
1.
Activate the verification.
Switch to the "Settings" tab.
In order to access force verification mode you
must be logged in.
2.
Press the "Force verification" button.
3.
Press the "Pulling unit" button.
4.
Press the "Force verification" button.
Inserting the closing force verification unit (1)
1.
Pull the locking hook (2) back.
2.
Insert the end of the tensioning strap fully into the
crimping cut-off head.
3.
Engage the locking hook (2) and the release it.
Issued April 2019
Fig. 4 "Settings" tab
1
Fig. 5 Inserting the closing force verification unit
Operation
2
9