Summary of Contents for Flare Fireplaces Flare 50 Series
Page 1
Read the installation, operating and maintenance instructions thoroughly before installing or servicing this equipment Flare Fireplaces Vent Free Outdoor Installation Guide Flare Double Corner, Left Corner, Right Corner, Front, See-Through and] v1.3...
FIREPLACE SAFETY WARNINGS WARNING WARNING DANGER! CARBON MONOXIDE HAZARD This appliance can produce carbon monoxide, which has no odor. Using it in an enclosed space can kill you. Never use this appliance in an enclosed space such as a camper, tent, car or home. WARNING Do not try to light this appliance without reading the “LIGHTING”...
Page 4
WARNING DANGER! HOT GLASS Hot glass and surface will cause burns. Do not touch glass until cooled. Never allow children to touch glass or surface surrounding the fireplace. WARNING Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Read the installation, operating and maintenance instructions thoroughly before installing or servicing this gas appliance.
Page 5
This appliance must not be used for cooking. This unit is not for use with solid fuel. Improper installation, adjustment, alteration, service, or maintenance can cause injury or property damage. Read the installation, operating and maintenance instructions thoroughly before installing or servicing this equipment.
Page 6
WARNING CAUTION! SAFE UNPACKING During unpacking and assembly, we recommended you wear work gloves and safety glasses for your protection. Although we make every effort to make the assembly process as problem free and safe as possible, it is characteristic of fabricated steel parts that the edges and corners might be sharp and could cause cuts if handled incorrectly.
Page 7
WARNING Use only non-combustible materials (certified to ASTM E-136) such as steel studs, cement board, ceramic tile, marble, paint etc. When adding finishing materials to the appliance. Do not use wood or drywall. WARNING You must have clear and easy access to the on/off valve AFTER the appliance is installed and connected to the gas supply in order to safely turn off the burner.
Page 8
RISK OF FIRE, EXPLOSION OR ASPHYXIATION, ENSURE THERE ARE NO IGNITION SOURCES SUCH AS SPARKS OR OPEN FLAMES. The installation must be performed by a licensed gas fitter, and all connections must be leak tested before operating the appliance. ...
Page 9
Children should be carefully supervised when they are in the area of the appliance. Clothing or other flammable materials should not be hung from the appliance or placed on or near the appliance. The area above the enclosure may be extremely hot. Direct contact with these surfaces should be avoided in order to prevent burns or clothing ignition.
Page 10
WARNING This conversion must be performed by a licensed gas fitter, and all connections must be leak tested before operating the appliance. WARNING If these instructions are not followed exactly, a fire causing death or serious injury may occur. WARNING A fire will result if the gas supply hose makes contact with the underside of the appliance.
Page 11
WARNING Never use this appliance for other than the intended use. Do not use this appliance to prepare food. You must have clear and easy access to the on/off valve AFTER the appliance is installed and connected to the gas supply in order to safely turn off the burner. ...
FLARE FIREPLACES – FRAMELESS IN EVERY WAY Flare Fireplaces is where innovation, quality and luxury come together to form new ideas. By combining superior raw materials, contemporary design, creative technology and a frameless way of thinking, we have created a full line of direct-vent fireplaces that are luxurious, simple to operate, and efficient.
MANUAL MODEL LIST & INTRODUCTION The Following manual should be used for the following Flare Fireplaces 50 to 100 inch long. The Flare Firepalces outdoor ventfree fireplace can be ordered in the following confirmation Flare Front 50-100 “ ...
Page 14
Water & Moisture Resistance This outdoor fireplace will shed moderate amounts of water, but is not waterproof. Water and condensing water vapor may enter the chase under certain conditions. Do not locate appliance where it can get excessively wet. The fireplace will not perform as an exterior wall. Moisture penetration must be considered for construction that places the fireplace in structure walls or on moisture sensitive surfaces.
OUTDOOR FIREPLACE INSTALLATION When selecting a location for your appliance it is important to ensure clearances to adjacent combustibles are met. This appliance is intended for installation on an outdoor patio or in your yard. It is highly recommended that this appliance be installed in a sheltered area (following the guidelines outlined below).
Page 16
Within a partial enclosure which includes an overhead cover and no more than two side walls. These side walls may be parallel, as in a breezeway or at right angles to each side Within a partial enclosure which includes an overhead cover and three sidewalls, as long as 30 percent or more of the horizontal periphery of the enclosure is permanently open.
Risk of fire, explosion or asphyxiation. Ensure no ignition, flame or spark are near during installation. This includes cigarettes or cell phones. DRAIN & VENTILATION PLANNING Although the fireplace is designed to operate outdoors safely, rain and other sources of moisture may enter the fireplace area, which will cause water to collect inside the chase and base of the unit within the fireplace enclosure.
CLEARANCES Clearance to combustible framing Top ............4” (0 mm) Bottom.............0” (0 mm) Side............2” (0 mm) Back ............2” (0 mm) Perpendicular Sidewall combustibles....36” Top of unit to ceiling ......36” (914 mm) Front of unit to combustibles.....36” (914 mm ) Clearance to combustible finishing Index Letter Description Dimension from Fireplace Opening (in inches )
MANTEL CLEARANCE The use of non-combustible material for mantel is recommended. If using combustible materials, follow the chart below. Note: When using paint or lacquer to finish the mantel, the paint or lacquer must be heat resistant to prevent discoloration. Warning! Do not attach combustible material to the mantel of your fireplace.
ELECTRICAL REQUIRMENTS Use only a Ground Fault Interrupter (GFI) protected circuit with this outdoor gas appliance installed near the fireplace. Wiring to the junction box must be metal clad or enclosed in a conduit and must be approved for outdoor use.
LED LIGHT The Flare Fireplaces is shipped with a multi-color interior RGB LED lighting installed and connected. The lights allow perfect flames to be viewed across a bed of illuminated crushed glass. RGB LED – Multi color option controlled by a remote control for color selection. Once the color has been selected by the operator, next time LED is turn use, system will remember and maintain color selected.
VENT FREE – FLARE FIREPLACES – SPECIFICATION Opening Propane Type Model name Shape Height NG BTU Flare 50 Flare-VF-FF-50 Front 16" Flare 50 Flare-VF-FF-50-H Front 24" Flare 60 Flare-VF-FF-60 Front 16" Flare 60 Flare-VF-FF-60-H Front 24" Flare 70 Flare-VF-FF-70 Front 16"...
Page 23
Opening Propane Type Model name Shape Height NG BTU Flare 50 Flare-VF-DC-50 Double Corner - Bay 16" Flare 50 Flare-VF-DC-50-H Double Corner - Bay 24" Flare 60 Flare-VF-DC-60 Double Corner - Bay 16" Flare 60 Flare-VF-DC-60-H Double Corner - Bay 24"...
MEDIA ARRANGEMENTS Flare Fireplace can be equipped with different media types. Follow the instruction below for information on how to add and arrange media in your Fireplace: Do not place any type of media on the pilot or in front of the pilot. Keep 1” distance from the pilot to allow correct operation of the pilot.
FIREPLACE WIND AND RAIN COVERS The Fireplace covers are design to be used during storage time only. Make sure to remove the covers prior use. Never operate the fireplace with any of the covers attached to the unit (Front or sides). Remove all covers PRIOR to attempting to start the fireplace The fireplace covers are only for storage DO NOT START THE FIREPLACE WITH THE COVERS ATTCHED...
INSTALLATION STEPS 1. Prior to starting the installation, make sure you read and understand all WARNING information in the manual. Do not start the installation if you are not clear about any of the installation related subjects. 2. Determine the following: ...
FIREPLACE UNPACKING Follow the instructions below for unpacking the unit: Check the packing and confirm there is no external damage. If damage exists, please notify Flare Fireplaces immediately. Remove the top wood studs and pull the external carton box up.
REPLACEMENT PARTS See below for flare replacement part list. Please contact your fireplace dealer in order to purchase any replacement part. Please make sure to provide the description and part number. Please make sure to use a certified installer for any service related to your fireplace. 29 | P a g e...
MAINTENANCE WARNING! It is recommended that a qualified service technician perform a routine inspection at the beginning of each heating season. Disconnect power before attempting maintenance or repair of the fireplace. Installation and maintenance must be performed by an authorized qualified installer, service agency or gas supplier.
Page 31
Pilot Maintenance Visually inspect the pilot flame. The pilot flame should be always present when the fireplace is in operation. Make sure the pilot flame has two flame tips pointing to the flame sensor (thermocouple) and to the center of the burner.
APPENDIX MAINTENANCE LOG Flare Fireplaces – Maintenance log Following document should be used by the service technician. A copy should be kept with the technician and owner for future reference Service Date: ___________________ Unit Information Model Type and Size: ____________________________________________________...
Warranty coverage begins on the date of original purchase. It is the responsibility of the installer to ensure the appliance is firing as per the rating plate. Any part that is found in our judgment to be defective shall be repaired, replaced or refunded at Flare Fireplaces option.
Page 34
Flare Fireplaces is not responsible for televisions, mantles, surrounds or finishing material around the fireplace. Flare Fireplaces may at its discretion discharge all obligations by refunding the wholesale price of the defective part. The Limited Warranty covers only parts and labor as provided above. Flare Fireplaces will not be responsible for materials, components or construction, which are not manufactured or supplied by Flare Fireplaces or for the labor necessary to install, repair or remove such materials, components or construction.