You can control the blower either via the 0-10 VDC input or the
PWM input. Note: Inputs cannot be used simultaneously.

3.2 Nominal data

Motor
M1G055-AI
Nominal voltage / VDC
24
Nominal voltage
20 .. 28
range / VDC
Type of data definition
fa
Speed / min
-1
3950
Power input / W
45
Current draw / A
2.2
Min. ambient
-25
temperature
/ °C
Max. ambient
70
temperature
/ °C
ml = Max. load · me = Max. efficiency · fa = Running at free air
cs = Customer specs · cu = Customer unit
Subject to alterations

3.3 Technical features

Mass
1.2 kg
Size
126 mm
Surface of rotor
Thick layer passivated
Material of impeller
PA plastic
Housing material
Die-cast aluminium
Number of blades
18
Direction of rotation
Clockwise, seen on rotor
Type of protection
IP 00
Insulation class
"B"
Mounting position
Any
Condensate discharge
None
holes
Cooling bore / aperture
Rotor-side
Operation mode
S1
Premix
Suitable for pre-mixture.
Motor bearing
Ball bearing
Technical features
- Tach output
- Motor current limit
- PWM control input
Motor protection
Reverse polarity and locked-rotor
protection
Remark
Complete unit must be tested for required
approvals.
For cyclic speed loads, note that the rotating parts of the device
are designed for maximum one million load cycles. If you have
specific questions, contact ebm-papst for support.
Item no. 53368-5-9970 · Revision 81735 · Release 2014-01-29 · Page 5 / 9
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com
Operating instructions

3.4 Mounting data

For depth of screw, see chapter 3.1 Product drawing
; Secure the mounting screws against accidentally coming loose (e.g.
by using self-locking screws).
Strength class for
mounting screws
You can obtain additional mounting data from the product drawing if
necessary.

3.5 Transport and storage conditions

; Use the device in accordance with its protection type.
Max. permissible
ambient motor temp.
(transp./ storage)
Min. permissible
ambient motor temp.
(transp./storage)
8.8
+80 °C
-40 °C