3.2 Nominal data

Motor
M3G084-DF
Nominal voltage / VDC
110
Nominal voltage
77 .. 138
range / VDC
Type of data definition
ml
-1
Speed (rpm) / min
2600
Power input / W
475
Current draw / A
4.3
Min. ambient
-40
temperature / °C
Max. ambient
60
temperature / °C
ml = Max. load · me = Max. efficiency · fa = Running at free air
cs = Customer specs · cu = Customer unit
Subject to alterations

3.3 Technical features

Mass
4.44 kg
Size
280 mm
Motor size
84
Surface of rotor
Coated in black
Material of electronics
Die-cast aluminium
housing
Material of impeller
PA UL94 V0 plastic
Number of blades
6
Direction of rotation
Clockwise, seen on rotor
Type of protection
IP55
Insulation class
"F"
Humidity (F) /
H3
environmental
protection class (H)
Mounting position
Shaft horizontal or rotor on bottom; rotor
on top on request
Condensation
Rotor-side
drainage holes
Operation mode
S1
Motor bearing
Ball bearing; (sealed)
Technical features
- Output 10 VDC, max. 10 mA
- Operation and alarm display
- Alarm relay
- Run monitoring
- Output limit
- Motor current limit
- RS485 MODBUS RTU
- Soft start
-Maximum EEPROM write cycles
100,000
- Control input 0-10 VDC / PWM
- Control interface with SELV potential
safely disconnected from the mains
- Overvoltage detection
- Over-temperature protected
electronics / motor
- Line undervoltage detection
Motor protection
Thermal overload protector (TOP) wired
internally
Cable exit
Lateral
Item no. 53890-5-9970 · ENG · Revision 257061 · Release 2023-02-03 · Page 6 / 11
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com
Operating instructions
Safety classification
Product conforming
to standard
Approval
Remark
; Use the device in accordance with its protection type.
Notes on surface quality
The surfaces of the products conform to the generally applicable industrial
standard. The surface quality may vary during the production period.
Strength, dimensional stability and dimensional accuracy are not affected
by this.
The colour pigments of the paints used react perceptibly to UV light over
the course of time. To prevent the formation of patches and fading, the
product is to be protected against UV radiation. Changes in colour are
not a reason for complaint and are not covered by the warranty. UV
radiation in the frequency range and the intensity of natural solar radiation
has no effect on the technical properties of the products.

3.4 Mounting data

Any further mounting data required can be taken from the product
drawing or chapter 4.1 Connecting the mechanical system.
Strength class for
mounting screws
For depth of screw, see chapter 3.1 Product drawing
; Secure the mounting screws against accidentally coming loose (e.g.
by using self-locking screws).

3.5 Transport and storage conditions

Max. permissible
ambient motor temp.
(transp./ storage)
Min. permissible
ambient motor temp.
(transp./storage)
I; If a protective earth is connected by
the customer
This component to be built-in can have
several local protection class ratings. The
specification refers to the basic design of
this component.
The final protection class is based on
the intended installation and connection of
the component.
EN 15085-1, CPC3; EN 45545-2, HL3;
EN 50155; EN 61373, Cat. 1B
EAC
If voltage (e.g. 230 VAC) is passed
through the alarm relay, the SELV signal
wires lose their increased insulation,
meaning they only have basic insulation
The SELV property (increased
insulation) is not lost when voltages of up
to 110 VDC are passed through the
alarm relay.
8.8
+80 °C
-40 °C