2. PROPER USE

The device is exclusively designed as a built-in device for moving air
and gases according to its technical data.
Any other or secondary use is deemed improper and constitutes a
misuse of the device.
Installations on the customer's side must meet the mechanical, thermal
and service life-related stresses that can occur.
Proper use also includes:
Use the device in DC power systems only.
Moving a gas/air mixture in gas burners with H gas, L gas
and liquid gas according to gas family 2 and 3 in accordance with
the German DVGW (German Technical and Scientific Association
for Gas and Water),
worksheet 260, in a concentration of approx. 90 % air and 10 %
gas, integrated into
an overall system which is designed specifically for operation with
this gas type.
Moving air with a density ranging from 0.9 to 1.2 kg/m³.
Minding the operating instructions.
Using the device in accordance with the permitted ambient
temperature, see chapter 3.5 Transport and storage conditions and
chapter .
Only using the device in stationary systems.
Installing the device into an overall system for moving air/gas
mixtures.
Commissioning the built-in component only after installation in the
customer unit.
Operating the device with all protective features in place.
Improper use
Using the device in the following ways is particularly prohibited and
may cause hazards:
Operating the device with an imbalance, e.g. caused by dirt deposits
or icing.
Moving a medium that contains abrasive particles.
Moving a highly corrosive medium.
Moving a medium that contains dust pollution, e.g.
suctioning off saw dust.
Operating the gas blower in an environment that contains
flammable gases or dust or combustible solids or fluids.
Moving an air/gas mixture outside an overall system
that fulfils the requirements described above.
Using the blower as a safety component or for taking
on safety-related functions.
Operation in medical equipment with a life-sustaining or lifesaving
function.
Contact with materials that could damage blower parts, e.g. liquids
during cleaning.
Operation with completely or partially disassembled or modified
protective features.
Exposure to radiation which could damage blower parts, e.g. strong
UV radiation.
Operation with external vibrations.
Operating the device in an explosive atmosphere.
Item no. 53368-5-9970 · Revision 81735 · Release 2014-01-29 · Page 3 / 9
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com
Operating instructions
Operation with completely or partially disassembled or modified
protective features.
In addition, all application options that are not listed
under proper use.