Cleaning; Safety Test - ebm-papst G1G126-AB13-53 Operating Instructions Manual

Hide thumbs Also See for G1G126-AB13-53:
Table of Contents

Advertisement

G1G126-AB13-53
Mains supply
voltage faulty
Faulty connection
Overtemperature of
Insufficient cooling
electronics/motor
Ambient temperature
too high
Unacceptable
operating point
Deflagration
Leakage of the
handled air/gas
mixture
If you have any other problems, contact ebm-papst.

5.1 Cleaning

NOTE
The device does not need to be cleaned.

5.2 Safety test

What has to
How to test?
be tested?
Check the
Visual inspection At least every
protective
casing against
accidental
contact for
damage and to
ensure that it is
intact
Check the
Visual inspection At least every
device for
damage to
blades and
housing
Mounting the
Visual inspection At least every
connection lines
Check the
Visual inspection At least every
insulation of
the wires for
damage
Item no. 53368-5-9970 · Revision 81735 · Release 2014-01-29 · Page 9 / 9
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com
Operating instructions
Check mains supply
voltage,
restore power
supply,
apply control signal.
De-energise, correct
connection, see
connection diagram.
Improve cooling. Let
the device cool
down.
To reset the error
message, switch off
the mains supply
voltage for a min. of
25 s and switch it on
again.
Reduce the ambient
temperature.
Reset by reducing
control input to 0.
Correct the operating
point. Let the device
cool down.
Check for leaks;
replace blower if not
properly sealed
Frequency
Which
measure?
Repair or
6 months
replacement of
the device
Replacement
6 months
of the device
Fasten
6 months
Replace wires
6 months