Sony HDW-S2000 Operation Manual page 127

Sony hd digital videocassette recorder operation manual hdw-s2000, hdw-s2000p
Hide thumbs Also See for HDW-S2000:
Table of Contents

Advertisement

Menu items in the range 600 to 650, relating to the time code generator (Continued)
Item number Item name
602
VITC POSITION SEL-2
(Invalid in 24PsF or
23.98PsF mode)
603
ID CODE PRESET
604
ID CODE SW
605
TCG REGEN MODE
606
TC OUTPUT SIGNAL IN
REGEN MODE
607
U-BIT BINARY GROUP
FLAG
Settings
In 59.94i, 29.97PsF mode
Select a line to insert the VITC in. (For SD output)
12H to [18H] to 20H: Select any line from 12 to 20.
Note
You can insert the VITC signal in two places. To insert it in two places, set both
items 601 and 602.
In 50i, 25PsF mode
Select a line to insert the VITC in. (For SD output)
9H to [21H] to 22H: Select any line from 9 to 22.
Note
You can insert the VITC signal in two places. To insert it in two places, set both
items 601 and 602.
Select whether or not to set the ID code.
[OFF]: Do not set the ID code.
ON: Set the ID code.
To set the ID code:
Press the F5 (SET) button with this menu item displayed in the menu display, to
enter the ID code setting mode. You can then set the user ID digit by digit using
the T and t buttons for digit selection. When all required digits have been set
correctly, press the F5 (SET) button again to save the ID code and exit from the
ID code setting mode.
Select whether or not to record the ID code set using menu item 603 in the user
bits.
[OFF]: Record the normal data in the user bits.
ON: Record the ID code in the user bits.
Select the signals to be regenerated when the time code generator is in the
regeneration mode (i.e., when the function menu item PR/RGN (F2) is set to LTC
or VITC, or the unit is in automatic edit mode).
: Both the time code and user bit signals are regenerated.
TC&UB
TC: Only the time code signal is regenerated.
UB: Only the user bit signal is regenerated.
Select the signal output from the TIME CODE OUT connector during normal (×1)
speed playback:
[TAPE]: During tape playback, the playback time code signal is output without
regeneration.
REGEN : The playback time code is output after regeneration.
Select whether to generate time code automatically.
[000]: Character set not specified
001: 8-bit characters compliant with ISO 646 and ISO 2022
010: Undefined
011: Undefined
100: Undefined
101: SMPTE 262M page/line multiplex system
110: Undefined
111: Undefined
(Continued)
10-19
Chapter 10 Setup Menus

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hdw-s2000p

Table of Contents