Sk-Hd1300-S3 Connection Diagram - Hitachi SK-HD1300-S3 Service Manual

Table of Contents

Advertisement

No.
Item
1
Connection
2
Scene
Ambient temperature:
setting
Ambient humidity :
3
Shooting

SK-HD1300-S3 Connection diagram

Condition
The specified measuring instrument (lens, power supply,
WFM, noise meter and Pix monitor) must be wired as
shown in the connection diagram.
Set the grayscale chart to the viewer and adjust scene
illumination and color temperature to 2000lx, 3200K.
20±10℃
45 to 85%RH
Set the lens iris to F11 and make an adjustment of focusing
lens and zooming image to match the standard condition.
Shoot the chart as the eight arrows fit the edges of screen.
Procedure
4-3