5.5.6 PPWM (Solenoid current controller P gain)
5.5.7 IPWM (Solenoid current controller I gain)
Command
PPWM
IPWM
The PI current controller for the solenoids is parameterized with these commands.
CAUTION: These parameters should not be changed without adequate measurement facilities and
experiences.
Attention, if the parameter ACC is set to ON, these adjustments are done automatically.
If the PWM frequency is < 250 Hz, the dynamic of the current controller has to be decreased.
Typical values are: PPWM = 1... 3 and IPWM = 40... 80.
If the PWM frequency is > 1000 Hz, the default values of PPWM = 7 and IPWM = 40 should be chosen.
5.6
Process data (Monitoring)
Command
WR
WA
W
C
U
IA
IB
RV+
The process data are the variable values which can be continuously observed on the monitor or on the oscillo-
scope.
Page 24 of 27
Parameters
X
x= 0... 30
X
x= 1... 100
Description
Command value (real Unit)
Scaled command value
Command value after ramp function
Control signal
Output signal to power stage
Current to solenoid A
Current to solenoid B
Reference supply voltage
PAM-195-P-PVG
Unit
Group
-
ACC=OFF
-
Unit
V
%
%
%
%
mA
mA
V