Test J, Will Not Run On Dc Power - Norcold N10DCX Service Manual

Compressor refrigerators
Hide thumbs Also See for N10DCX:
Table of Contents

Advertisement

Troubleshooting Symptoms, cont'd.

Test J, Will Not Run On DC Power

N10DCX
Check for blown fuse in DC circuit.
YES
Is fuse
blown?
NO
Check that the wiring to the refrigerator
is at least #12 gauge wire (required).
NO
Is wiring at
least #12
gauge?
YES
Check DC voltage at control module.
NO
Is voltage
below 10.4
VDC?
YES
Recharge or replace battery.
Replace fuse.
Refer to the Installation Manual for
the recommended wire size.
Correct high resistance (voltage drop) in
supply circuit.
22