Installing The Mini Card - Siemens SIMATIC IPC377E Operating Instructions Manual

Hide thumbs Also See for SIMATIC IPC377E:
Table of Contents

Advertisement

Procedure - closing the device.
Close the device in reverse order.
6.2

Installing the Mini card

This device supports the below expansion cards:
● a half-size mini card: you can install a half-size mini PCIe card into this slot.
● a full-size mini card: you can install a mSATA card or a mini card with USB2.0 interface in
this slot
Note
Power consumption
If the power consumption of the Mini cards are too high, the device will be damaged.
Ensure that the power consumption amounts to a maximum of 1 W.
Ambient temperature
The temperature inside the IPC can be up to 25 °C above the maximum permissible ambient
temperature of the device.
Make sure that the maximum permissible ambient temperature of the Mini cards are
specified accordingly.
Note
If you want to use both of the two slots, insert the half-size mini card first.
Requirement
● The device is opened.
SIMATIC IPC377E
Operating Instructions, 06/2019, A5E40965249-AD
Expanding and assigning parameters to the device
Open up the device cover and set it along with the
drive vertically up against the side of the device.
Lay the cover aside.
Notice: Connection plug and board can be dam-
aged.
Ensure that the device cover does not fall
down.
Remove the connection plug from the drive.
6.2 Installing the Mini card