Operating instructions
Communications module ACM
WAVE SYSTEM RF for gas meters
with Absolute ENCODER AE2 with
and without smart valve
Translation from the German
© 2008 - 2010 Elster GmbH

Contents

ENCODER AE2 with and without smart valve 1
Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Safety. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Checking the usage . . . . . . . . . . . . . . . . . . . . . 2
Type code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Part designations . . . . . . . . . . . . . . . . . . . . . . . . 2
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Wiring the RECEIVER. . . . . . . . . . . . . . . . . . . . . 3
Installing the gas meter . . . . . . . . . . . . . . . . . . . 3
Attaching the TRANSMITTER. . . . . . . . . . . . . . . 3
Commissioning. . . . . . . . . . . . . . . . . . . . . . . . . 4
failed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Installing the REPEATER . . . . . . . . . . . . . . . . . . 4
TRANSMITTER. . . . . . . . . . . . . . . . . . . . . . . . . . 4
Finishing installation . . . . . . . . . . . . . . . . . . . . . . 4
Closing and sealing the REPEATER . . . . . . . . . . 4
Replacement. . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Technical data . . . . . . . . . . . . . . . . . . . . . . . . . 6
Declaration of conformity . . . . . . . . . . . . . . . . 6
Contact . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

Safety

Please read and keep in a safe place
Please read through these instructions
carefully before installing or operating. Following the
installation, pass the instructions on to the opera-
tor. This unit must be installed and commissioned
in accordance with the regulations and standards
in force. These instructions can also be found at
www.docuthek.com.
Explanation of symbols
• , 1 , 2 ,  ... = Action
= Instruction
Liability
We will not be held liable for damages resulting
from non-observance of the instructions and non-
compliant use.
Safety instructions
Information that is relevant for safety is indicated in
the instructions as follows:
DANGER
Indicates potentially fatal situations.
WARNING
Indicates possible danger to life and limb.
CAUTION
Indicates possible material damage.
All interventions may only be carried out by qualified
gas technicians. Electrical interventions may only be
carried out by qualified electricians.
Conversion, spare parts
All technical changes are prohibited. Only use OEM
spare parts.
Transport
On receipt of the product, check that the delivery is
complete (see Part designations). Report any trans-
port damage immediately.
Storage
Store the product in a dry place. Ambient tempera-
ture: see Technical data.
Disposal
Components, particularly batteries, are to be dis-
posed of separately.
On request, old units may be returned carriage paid
to Elster GmbH in accordance with the relevant waste
legislation requirements (for Germany: KrW-/AbfG
[Act for Promoting Closed Substance Cycle Waste
Management and Ensuring Environmentally Compat-
ible Waste Disposal]).
GB-1

Advertisement

loading

Summary of Contents for Elster ACM WAVE SYSTEM RF

  • Page 1: Table Of Contents

    Synchronizing the REPEATER failed ..4 to Elster GmbH in accordance with the relevant waste Finishing installation ..... . 4 legislation requirements (for Germany: KrW-/AbfG Closing and sealing the REPEATER .
  • Page 2: Communications Module Acm Wave

    SYSTEM RF for gas meters with Absolute ENCODER AE2 offers a wide range of mounting options. ACM WAVE SYSTEM RF for recording and forwarding ▷ To attach, excepting the oblong holes A , the absolute meter readings. open upper housing must be removed from the The “V-Drive”...
  • Page 3: Wiring The Receiver

    BK-G1.6 to BK-G25T, see www.docuthek. ▷ The RECEIVER is delivered with a prefabricated com → Elster-Instromet → Products → Gas connection cable. The RECEIVER may optionally measuring devices → Diaphragm meters → be delivered without a connection cable.
  • Page 4: Commissioning

    Commissioning TRANSMITTER 4 Move the REPEATER in the direction of the de- Installing the TRANSMITTER/RECEIVER ▷ The ACM WAVE SYSTEM RF units are delivered sired installation location and the TRANSMITTER. ▷ When doing this, the signal between the fully programmed.
  • Page 5: Replacement

    ? M-Bus communication with the RECEIVER Replacement is disturbed. ▷ The ACM WAVE SYSTEM RF units are matched ! The connection plug in the RECEIVER is not together in pairs. This means that once the bat- plugged in. tery life has expired, the complete ACM WAVE •...
  • Page 6: Technical Data

    M-BUS transfer of status and error messages in with communications module ACM WAVE SYSTEM accordance with EN 13757. RF, ACM WAVE SYSTEM RF V-Drive and ACM WAVE REPEATER RF for gas meters BK-G comply with the ACM WAVE RECEIVER RF requirements of the listed Directives and Standards: Power supply via M-BUS: 6 mA (4 M-Bus loads).