Elster Kromschroder VMF Operating Instructions Manual
Elster Kromschroder VMF Operating Instructions Manual

Elster Kromschroder VMF Operating Instructions Manual

Filter module, measuring orifice, fine-adjusting valve

Advertisement

Filter module VMF, Measuring orifice VMo,
Fine-adjusting valve VMV
Contents
Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Changes to edition 11.18 . . . . . . . . . . . . . . . . . . 1
Checking the usage . . . . . . . . . . . . . . . . . . . . . . 2
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Tightness test . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Commissioning . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Designed lifetime. . . . . . . . . . . . . . . . . . . . . . . . . 8
Logistics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Certification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
oPeRAtInG InstRUCtIons
· Edition 01.20 · 03250879 · EN

sAFetY

Please read and keep in a safe place
Please read through these instructions care-
fully before installing or operating. Following the installa-
tion, pass the instructions on to the operator. This unit
must be installed and commissioned in accordance
with the regulations and standards in force. These
instructions can also be found at www.docuthek.com.
explanation of symbols
1  , 2  , 3  , a  , b  , c  = Action
➔ = Instruction
Liability
We will not be held liable for damage resulting from
non-observance of the instructions and non-com-
pliant use.
safety instructions
Information that is relevant for safety is indicated in the
instructions as follows:
DAnGeR
Indicates potentially fatal situations.
WARnInG
Indicates possible danger to life and limb.
CAUtIon
Indicates possible material damage.
All interventions may only be carried out by qualified
gas technicians. Electrical interventions may only be
carried out by qualified electricians.
Conversion, spare parts
All technical changes are prohibited. Only use OEM
spare parts.

CHAnGes to eDItIon 11.18

The following chapters have been changed:
- Checking the usage
- Installation
- Commissioning
- Certification

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Kromschroder VMF and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Elster Kromschroder VMF

  • Page 1: Table Of Contents

    Filter module VMF, Measuring orifice VMo, Fine-adjusting valve VMV oPeRAtInG InstRUCtIons · Edition 01.20 · 03250879 · EN sAFetY Please read and keep in a safe place Please read through these instructions care- fully before installing or operating. Following the installa- tion, pass the instructions on to the operator.
  • Page 2: Checking The Usage

    Part designations CHeCKInG tHe UsAGe Intended use valVario filter module VMF, measuring orifice VMO and fine-adjusting valve VMV for installation in gas control and safety systems in the fields of industrial and com- mercial gas heat generation. with replaceable filter pad insert to protect against soiling of downstream appliances.
  • Page 3: Tightness Test

    ing orifice, the VMO is fitted downstream of the control. VMV, VMO ➔ Installation position with inlet and outlet flang- es: VMF, VMV and VMO may be inserted at any position in the pipework. When used as a measuring orifice, the length of the inlet and ➔...
  • Page 4: Commissioning

    9 Insert the new sealing ring (included in the delivery) CoMMIssIonInG when fitting the new orifice plate. The sealing ring may be greased lightly, e.g. with Klüber Nontrop ZB91. setting the flow rate ➔ At the factory, the fine-adjusting valve VMV is adjusted for maximum flow rate (100%).
  • Page 5: Accessories

    ACCessoRIes VMO 110/115 orifice plate Orifice insert for installing in the plate bracket of meas- uring orifice VMO. The hole diameter is engraved on the orifice insert. Supply including the new seal for the base plate. Hole dia. 8 10 orifice order no.
  • Page 6 VMO 340 VMO 232 5 6 8 10 40 60 80 100 VMO 240 VMO 350 5 6 8 10 40 60 40 60 400 600 1000 [m³/h] VMO 250 VMO 365 30 40 60 80 100 400 600 60 80 100 [m³/h] EN-6...
  • Page 7: Technical Data

    Filter pad set seal set for sizes 1–3 When retrofitting accessories or a second valVario control or when servicing, we recommend replacing the seals. Filter pad set for size 1: Order No. 74923800 Filter pad set for size 2: Order No. 74923801, Filter pad set for size 3: Order No.
  • Page 8: Designed Lifetime

    VMV: air flow rate Q for a pressure loss of Δp = 1 mbar: DesIGneD LIFetIMe ∆p = 1 mbar This information on the designed lifetime is based on using the product in accordance with these operat- ing instructions. Once the designed lifetime has been reached, safety-relevant products must be replaced.
  • Page 9: Certification

    The relevant product corresponds to the tested type sample. The production is subject to the surveillance proce- dure pursuant to Regulation (EU) 2016/426 Annex III paragraph 3. Elster GmbH Scan of the Declaration of conformity (D, GB) – see www.docuthek.com eurasische Zollunion The products VMV meet the technical specifications of the Eurasian Customs Union.
  • Page 10 Honeywell Sales Engineer. Elster GmbH Strotheweg 1, D-49504 Lotte T +49 541 1214-0 hts.lotte@honeywell.com www.kromschroeder.com Global centralized service deployment coordination: Translation from the German T +49 541 1214-365 or -555 hts.service.germany@honeywell.com © 2020 Elster GmbH EN-10...

This manual is also suitable for:

Kromschroder vmoKromschroder vmv