INSTALLATION / HANDLING
ELECTRICAL DATA — UP6 5
Standard voltage
Full load current (maximum)
Starting current DOL (Star Delta)
Starting time DOL (Star Delta)
Starts per hour (maximum)
Control voltage
Recommended fuse rating See note 1
Recommended wire size AWG See note 2
ELECTRICAL DATA — UP6 7.5
Standard voltage
Full load current (maximum)
Starting current DOL (Star Delta)
Starting time DOL (Star Delta)
Starts per hour (maximum)
Control voltage
Recommended fuse rating See note 1
Recommended wire size AWG See note 2
ELECTRICAL DATA — UP6 10
Standard voltage
Full load current (maximum)
Starting current DOL (Star Delta)
Starting time DOL (Star Delta)
Starts per hour (maximum)
Control voltage
Recommended fuse rating See note 1
Recommended wire size AWG See note 2
ELECTRICAL DATA — UP6 15c
Standard voltage
Full load current (maximum)
Starting current DOL (Star Delta)
Starting time DOL (Star Delta)
Starts per hour (maximum)
Control voltage
Recommended fuse rating See note 1
Recommended wire size AWG See note 2
1. If a circuit breaker is selected it should only be a magnetic trip type,
set above the anticipated starting current of the machine, but below the
maximum prospective fault current for the circuit. The circuit breaker
or fuseable disconnect must be capable of breaking the prospective
fault current at its terminals.
2. PVC/PVC Type Calculated using the following conditions:
en
230V/1PH
200V
23.5A
15.5A
3–5 Sec (7–10 Sec)
40A
25A
8
10
230V/1PH
200V
34.1A
26.5A
3–5 Sec (7–10 Sec)
50A
35A
6
8
230V/1PH
200V
29.8A
3–5 Sec (7–10 Sec)
50A
8
230V/1PH
200V
43.2A
3–5 Sec (7–10 Sec)
75A
4
i) PVC insulated cable, armoured, copper conductors.
ii) Cable clipped to a wall, in free air.
iii) Ambient temperature of 40_C (104_F) and relative humidity of 40%.
iv) 20m (65ft) cable run.
v) Volt drop limited to –10% during starting, –4% during normal
running.
vi) Protected by the circuit breaker listed above.
230V/3PH
460V
13.5A
6.8A
6
120VAC
20A
10A
12
14
230V/3PH
460V
23.1A
11.5A
6
120VAC
35A
15A
10
14
230V/3PH
460V
26.0A
13.0A
6
120VAC
45A
20A
8
12
230V/3PH
460V
37.6A
18.8A
6
120VAC
65A
30A
6
10
575V
5.4A
8A
14
575V
9.2A
12A
14
575V
10.3A
15A
14
575V
15.1A
25A
10