Inspection & Maintenance; After Use; Maintenance - Atexor Slam Trans 200 EX Instructions For Safe Use

Table of Contents

Advertisement

When connecting relating equipment to the Slam® Trans please observe the operational
characteristics of the equipment in case and ensure that above mentioned special conditions
are passed.
Inspection & Maintenance

4.1 After Use

Take the following steps after the Slam® Trans –unit has been taken out from Ex –area:
1) Clean the unit with a damp cloth (do not use detergents or solvents)
2) Have a visual check on the unit (condition of cable, enclosure, tightness of parts)
3) Let the unit dry in open air

4.2 Maintenance

The following procedure should be taken in case the Slam® Trans -unit needs to be repaired:
1) Maintenance may be carried out only outside Ex –area
2) Person responsible for maintenance should have been trained the basics of explosion-
protection as well electricity
3) Only original spare parts from the manufacturer should be used. Please note that there
are no components in this unit which can be repaired by using glue, silicone or any
other similar method.
4) Maintenance instructions with exploded-view diagram and spare parts list are available
at your local distributor and the manufacturer. Please, when requesting maintenance
instructions with exploded-view diagrams, include the model and serial number of the
product.