2/16 Contents Instructions for Safe Use .............................1 Introduction to Slam® Trans.........................3 1.1 Technical data ............................3 1.1.1 2P+E system (PELV)) ..........................4 1.1.2 2P system (SELV) ..........................4 1.1.3 3P system (SELV) ..........................4 1.2 Certification of equipment ..........................4 1.3 Standard unit construction .........................6 1.4 Quality Guaranteed ...........................7 1.4.1 General ...............................7 1.4.2 Individual testing reports ........................7...
3/16 Introduction to Slam® Trans (Certification N:o VTT 10 ATEX 011 Issue 3) This instruction manual guides you through the process of selecting and adopting Slam® Trans –transformer for your work site. The manual regards the following Slam® Trans -types: 1.1 Technical data Slam®...
4/16 1.1.1 2P+E system (PELV)) 1.1.2 2P system (SELV) 1.1.3 3P system (SELV) 1.2 Certification of equipment The Slam® Trans–series has been designed, tested and certified (according to ATEX) for portable use. There is no “X” –mark in the certificate for special conditions of safe use of the equipment.
Page 5
5/16 and local applicable laws. Local, national certificates of these units may exist outside the region of EU. The transformer is to be used properly and according to its ratings, documentation and local applicable laws. Local, national certificates of these units may exist outside the region of EU. The aforementioned Slam®...
Shortcircuit is definitely a source of ignition which may cause an explosion ! Other common accessories (optional): To view options on accessories, please visit www.Atexor.com for further study...
7/16 1.4 Quality Guaranteed 1.4.1 General The Slam® Trans–series is designed, certified, manufactured and tested under ISO 9001:2000 quality system as well as additional requirements of the Directive 94/9/EC (ATEX). The Slam® Trans–series is designed and tested according to the latest directives and standards.
8/16 The unit is plugged-in and checked that it is working properly after all accomplished tests above. Visual inspection A final check to see everything is fine (screws attached properly, wires connected and required markings attached). Prior to use 2.1 Selection of right equipment You need to be sure that the equipment you intend to take into explosion hazardous area matches up with the zone classification and other safety requirements related.
9/16 hazardous areas there are three equipment categories. Slam® -units mentioned in this instruction fall into Category 2 equipment. Category 1 product is suitable for use in Zones 0, 1 and 2 / (20, 21 and 22) Category 2 product is suitable for use in Zones 1 and 2 / 21 and 22 Category 3 product is suitable for use in Zones 2 / (22) 2.1.3 Gas explosion group (IIA, IIB or IIC) in accordance with Equipment group (IIA, IIB or IIC)
10/16 2.1.5 Environmental criteria Please observe the ambient temperature of the application in use because certification is valid for temperatures between – 20°C --- + 50°C. Please see type label of the product for further data. If the equipment is used in other temperatures than mentioned the safety can not be guaranteed.
11/16 3.3 Special attention on 3-pole use (24 V or 42 V) Using Slam® Trans -unit with 3-pole socket outlets (with bonding) is a simple way to solve the problems with static electricity of relating equipment. By connecting the bonding cable (supplied with transformer) to the local equipotential system at the site the secondary side sockets do have correct potential.
12/16 When connecting relating equipment to the Slam® Trans please observe the operational characteristics of the equipment in case and ensure that above mentioned special conditions are passed. Inspection & Maintenance 4.1 After Use Take the following steps after the Slam® Trans –unit has been taken out from Ex –area: 1) Clean the unit with a damp cloth (do not use detergents or solvents) 2) Have a visual check on the unit (condition of cable, enclosure, tightness of parts) 3) Let the unit dry in open air...
13/16 4.3 Testing Tests are to be done according to EN 60079-19 until returning the repaired unit back to operation. Below mentioned tests shall be done in addition to the tests specified in EN 60079- · PE –resistance test · High-voltage test (500 VDC between Phase& Neutral against P/E conductor) ·...
16/16 Helpdesk Under any doubt or question, please contact your local distributor or the manufacturer. Contact details: Phone: +358 20 734 3250 Fax: +358 20 734 3299 Email: info@atexor.com Web: http://www.atexor.com...