ADvAnCED PARAMETERS
Available settings: 1-99 - power change in percent
Default setting:
12. Power reporting interval
This parameter defines how frequently standard power reports (pa-
rameter 11) are sent. By default the Wall Plug sends up to 5 reports
each 30 seconds, provided the power load changes by 15%.
Available settings: 5-600 (in seconds)
Default setting:
13. Energy reporting threshold
This parameter specifies the minimum change in energy consump-
tion (in relation to the previously reported), that will result in sending
a new report.
Available settings: 0 - energy reports inactive
Default setting:
14. Power and energy periodic reports
This parameter defines time period between reports sent when
changes in power load have not been recorded or if changes are in-
significant (not exceeding values of parameters 20, 21 and 23). By de-
fault reports are sent every hour.
Available settings: 0 - periodic reports inactive
Default setting:
15. Measuring energy consumed by the Wall Plug itself
This parameter determines whether energy metering should include
the amount of energy consumed by the Wall Plug itself. Results are
being added to energy consumed by controlled device.
Available settings: 0 - function inactive
Default setting:
GROUP 20. „ON/OFF" ASSOCIATION GROUPS
20. Control of „On/Off (Button)" association group (2) devices
Controlling devices with the B-Button. This parameter is inactive in
"Always On" mode (parameter 1).
Control as the Wall Plug:
switching the Wall Plug on – switch the devices on (parameter 24)
switching the Wall Plug off – switch the devices off (parameter 24)
100 - reports are disabled
15 (15%)
Parameter size:
30 (30s)
Parameter size:
1-500 (0.01-5kWh, step 0.01kWh) - threshold
10 (0.1kWh)
Parameter size:
5-32400 (in seconds)
3600 (1h)
Parameter size:
1 - function activated
0
Parameter size:
1 [byte]
2 [bytes]
2 [bytes]
2 [bytes]
1 [byte]