Huvitz HS-5000 5X Operator's Manual

Huvitz HS-5000 5X Operator's Manual

Slit lamp microscope

Advertisement

-------------------------------------------------------------------------------------SLIT LAMP HS-5000 5X 1
Operator's Manual
SLIT LAMP MICROSCOPE HS-5000 5X

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HS-5000 5X and is the answer not in the manual?

Questions and answers

Summary of Contents for Huvitz HS-5000 5X

  • Page 1 -------------------------------------------------------------------------------------SLIT LAMP HS-5000 5X 1 Operator’s Manual SLIT LAMP MICROSCOPE HS-5000 5X...
  • Page 2 The information in this publication has been carefully checked and is believed to be entirely accurate at the time of publication. HUVITZ assumes no responsibility, however, for possible errors or omissions, or for any consequences resulting from the use of the information...
  • Page 3 -------------------------------------------------------------------------------------SLIT LAMP HS-5000 5X 3 HUVITZ reserves the right to make changes in its products or product specifications at any time and without prior notice, and is not required to update this documentation to reflect such changes. ©2006 HUVITZ Co., Ltd.
  • Page 4: Table Of Contents

    4 SLIT LAMP HS-5000 5X------------------- ---------------------------------------------------------------- Contents Introduction ........................6 1.1. Outline of the instrument..................6 1.2. Classification....................6 Safety Information......................7 2.1. Introduction ......................7 2.2. Safety Symbols ....................8 2.3. Environment factors ..................10 2.4. Safety Precautions..................12 Features & Operating Condition................14 3.1. Brief Description.....................14 3.2.
  • Page 5 -------------------------------------------------------------------------------------SLIT LAMP HS-5000 5X 5 10.1. Halogen Projection bulb ................29 10.2. Protection fuses replacement ................ 31 10.3. Cleaning & Disinfection ................. 32 11. EMC Information ...................... 33 11.1. Guidance and manufacturer’s declaration – electromagnetic emissions ..33 11.2. Guidance and manufacturer’s declaration – electromagnetic immunity ..34 11.3.
  • Page 6: Introduction

    6 SLIT LAMP HS-5000 5X------------------- ---------------------------------------------------------------- Introduction 1.1. Outline of the instrument The device works like all slit lamps: stereomicroscopic examination of the eye under the slit light. microscopic examination of the ocular fundus and posterior vitreous body (using hubry’s lens).
  • Page 7: Safety Information

    -------------------------------------------------------------------------------------SLIT LAMP HS-5000 5X 7 Safety Information 2.1. Introduction Safety is everyone’s responsibility. The safe use of this equipment is largely dependent upon the installer, user, operator, and maintainer. It is imperative that personnel study and become familiar with this entire manual before attempting to install, use, clean, service or adjust this equipment and any associated accessories.
  • Page 8: Safety Symbols

    8 SLIT LAMP HS-5000 5X------------------- ---------------------------------------------------------------- 2.2. Safety Symbols The International Electrotechnical Commission (IEC) has established a set of symbols for medical electronic equipment which classify a connection or warn of any potential hazards. The classifications and symbols are shown below.
  • Page 9 -------------------------------------------------------------------------------------SLIT LAMP HS-5000 5X 9 MEDICAL EUIPMENT WITH RESPECT TO ELECTRIC SHOCK UL60601-1 FIRE MECHANICAL HAZARDS CAN/CSA C22.2 ONLY IN ACCORDANCE WITH UL 60601- NO.601.1 1, AND CAN/CSA C22.2 NO.601.1 Disposal of your old appliance When this crossed-out wheeled bin symbol is attached to a product it means the product is covered by the European Directive 2002/96/EC.
  • Page 10: Environment Factors

    10 SLIT LAMP HS-5000 5X------------------- ---------------------------------------------------------------- 2.3. Environment factors Avoid the following environments for operation or storage: Where the equipment is exposed to water vapor. Don’t operate an equipment with a wet hand. Where the equipment is exposed to direct sunlight.
  • Page 11 -------------------------------------------------------------------------------------SLIT LAMP HS-5000 5X 11 Where equipment is exposed to chemical material or explosive gas. Be careful not to be inserted dust, especially, metal. Don’t disassemble the product or open. We aren’t responsible for it for nothing. Be careful not to close the fan located on the lateral or back side of the equipment.
  • Page 12: Safety Precautions

    The equipment must be operated only by, or under direct supervision of a properly trained and qualified person. Modifications of this equipment may only be carried out by Huvitz’s service technicians or other authorized persons. Customer maintenance of this equipment may only be performed as stated in the User’s Manual and Service Manual.
  • Page 13 This equipment may only be used together with accessories supplied by Huvitz’s. If the customer makes use of other accessories, use them only if their safe usability under technical safety aspects has been proved and confirmed by Huvitz or the manufacturer of the accessory.
  • Page 14: Features & Operating Condition

    14 SLIT LAMP HS-5000 5X------------------- ---------------------------------------------------------------- Features & Operating Condition 3.1. Brief Description The device works like all slit lamps: stereomicroscopic examination of the eye under the slit light. microscopic examination of the ocular fundus and posterior vitreous body (using hubry’s lens).
  • Page 15 -------------------------------------------------------------------------------------SLIT LAMP HS-5000 5X 15 CAUTION Because prolonged intense light exposure can damage the retina, the use of the device for ocular examination should not be unnecessarily prolonged, and the brightness setting should not exceed what is needed to provide clear visualization of the target structures.
  • Page 16: Standard Components

    16 SLIT LAMP HS-5000 5X------------------- ---------------------------------------------------------------- Standard Components The instrument is delivered in package. Taking it out of the package, make sure that none of the following parts is missing. A table top(N.B. the table top isn’t supplied with the slit lamp for twin table) on which are placed: A SMPS box(15) including the main switch &...
  • Page 17: Accessories

    -------------------------------------------------------------------------------------SLIT LAMP HS-5000 5X 17 Accessories The following standard accessories are provided with the instrument; protection cover(46) a setting rod(43) spare bulbs 12V 30W Halogen bulb(53) chin-rest paper(47) spare fuses 250Vac T2.0AL a breath screen(5) power cable [ Figure 1. Accessories ]...
  • Page 18: Composition

    18 SLIT LAMP HS-5000 5X------------------- ---------------------------------------------------------------- Composition Fixation point Control lever for changing enlargement Removable eye-pieces Knob for clamping the breath screen Breath screen Control handle for the slit rotation 90-0-90 Connecting plug of the projector lamp Knurled ring for filters insertion...
  • Page 19 -------------------------------------------------------------------------------------SLIT LAMP HS-5000 5X 19 26) Locking pins for chin rest paper 27) Chin rest 28) Knobs to change the slit width 29) Pointer for the eye positioning 30) Head rest 31) Microscope 32) Bulb feeding contacts 33) Knob to lock the base of the instrument...
  • Page 20 20 SLIT LAMP HS-5000 5X------------------- ---------------------------------------------------------------- 54) Bulb fastening knob 55) Mirror 56) Capture connector ( For the image system) 57) Capture switch 58) Luminosity selector connector ( Connect the Luminosity selector to the SMPS) 59) Head rest module...
  • Page 21 -------------------------------------------------------------------------------------SLIT LAMP HS-5000 5X 21 [ Figure 2. Composition I ]...
  • Page 22 22 SLIT LAMP HS-5000 5X------------------- ---------------------------------------------------------------- [ Figure 3. Composition Ⅱ]...
  • Page 23: Installation

    -------------------------------------------------------------------------------------SLIT LAMP HS-5000 5X 23 Installation NOTE The appliances are always supplied with excellent packaging to be able to stand up to all kinds of transport and standard storage conditions. Please contact the suppliers if any irregularities are found in the appliance due to transport after unpacking 7.1.
  • Page 24 24 SLIT LAMP HS-5000 5X------------------- ---------------------------------------------------------------- Place the head rest module(59) and make sure that its holes fit together with those of the table top. Tighten the screw with the screw driver [ Figure 5. Assembling the instrument I] Place the base with orthogonal movements on the guides situated on the upper part of the table top, checking that the wheels are in line.
  • Page 25 -------------------------------------------------------------------------------------SLIT LAMP HS-5000 5X 25 Assemble An optical group of the slit projector(49) on the Base with orthogonal movements(10). Then tighten the Guide screw with the screw driver(-) Put the microscope(31) in the right position making sure that it is placed well in the stop(37);...
  • Page 26 26 SLIT LAMP HS-5000 5X------------------- ---------------------------------------------------------------- [ Figure 6. Assembling the instrument Ⅱ]...
  • Page 27: Trial Operations

    -------------------------------------------------------------------------------------SLIT LAMP HS-5000 5X 27 Trial Operations Assemble the chin-rest paper(47) on the chin-rest(27). Let the patient sit down comfortable with his chin on the chin-rest and his forehead against the forehead-rest. Lift or lower the chin-rest by moving the handle (25) so that the patient’s eyes are in line with the notches on the chin-rest(29) Switch the instruments on, press the switch(13).
  • Page 28: Main Features

    28 SLIT LAMP HS-5000 5X------------------- ---------------------------------------------------------------- Main Features Principal operative characteristics of the instrument: Observation without settling or tiring and rapid change of enlargements. Base with cross-wise movement (which can be stopped) commanded by a single joystick for all adjustments(x y z) Stereomicroscopical observation of the eye with enlargements 6X-10X-16X-25X- 40X(5 enlargements model).
  • Page 29: Ordinary Maintenance

    -------------------------------------------------------------------------------------SLIT LAMP HS-5000 5X 29 10. Ordinary Maintenance WARNING The repairs illustrated below should all be carried out with the power cable disconnected from the main supply plug. Please contact the suppliers for any other problems that cannot be resolved by the operations described below.
  • Page 30 30 SLIT LAMP HS-5000 5X------------------- ---------------------------------------------------------------- touch the bulb whit fingers) Fasten the bulb with the knob Make sure that the stems of the bulb are completely inserted; insert the plug in the main supply socket [ Figure 7. Replace Halogen bulb ] WARNING Don’t Touch to the Lamp House, During the Operation.
  • Page 31: Protection Fuses Replacement

    -------------------------------------------------------------------------------------SLIT LAMP HS-5000 5X 31 10.2. Protection fuses replacement To replace the fuses proceed as follows: The protection fuses are placed on the back of the SMPS, and inserted power socket. Before doing anything else, disconnect the plug from the main supply...
  • Page 32: Cleaning & Disinfection

    32 SLIT LAMP HS-5000 5X------------------- ---------------------------------------------------------------- 10.3. Cleaning & Disinfection To keep the device clean, apply clinical alcohol and cidex or cidex plus on a soft cloth and scrub the body and the probe once a month. Do not use lacquer, thinner, ethylene, or the oxidizing substance.
  • Page 33: Emc Information

    -------------------------------------------------------------------------------------SLIT LAMP HS-5000 5X 33 11. EMC Information 11.1. Guidance and manufacturer’s declaration – electromagnetic emissions The EUT is intended for use in the electromagnetic environment specified below. The customer or the user of the EUT should assure that it is used in such an environment.
  • Page 34: Guidance And Manufacturer's Declaration - Electromagnetic Immunity

    34 SLIT LAMP HS-5000 5X------------------- ---------------------------------------------------------------- 11.2. Guidance and manufacturer’s declaration – electromagnetic immunity The EUT is intended for use in the electromagnetic environment specified below. The customer or the user of the EUT should assure that it is used in such an environment.
  • Page 35 -------------------------------------------------------------------------------------SLIT LAMP HS-5000 5X 35 <5% Uт Uт ) EUT image intensifier be (<95% dip in for 5 s powered from Uт ) uninterruptible power for 5 s supply or a battery. Power frequency 3 A/m 3 A/m Power frequency...
  • Page 36: Guidance And Manufacturer's Declaration - Electromagnetic Immunity

    36 SLIT LAMP HS-5000 5X------------------- ---------------------------------------------------------------- 11.3. Guidance and manufacturer’s declaration – electromagnetic immunity The EUT is intended for use in the electromagnetic environment specified below. The customer or the user of the EUT should assure that it is used in such an environment.
  • Page 37 -------------------------------------------------------------------------------------SLIT LAMP HS-5000 5X 37 and d is the recommended separation distance in meters (m). Field strengths from fixed RF transmitters, as deter-mined by an electromagnetic site survey, should be less than the compliance level in each frequency range. Interference may occur in the vicinity of...
  • Page 38: Recommended Separation Distances Between Portable And Mobile Rf

    38 SLIT LAMP HS-5000 5X------------------- ---------------------------------------------------------------- 11.4. Recommended separation distances between portable and mobile RF communications equipment and the EUT The is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled. The customer or the user of the EUT can help Prevent...
  • Page 39: Immunity And Compliance Level

    -------------------------------------------------------------------------------------SLIT LAMP HS-5000 5X 39 11.5. Immunity and Compliance Level Immunity test IEC 60601 Test Actual Immunity Compliance Level Level Level Conducted RF 3Vrms 3Vrms 3Vrms IEC 61000-4-6 150kHz to 80MHz Radiated RF 3Vrms 3V/m 3V/m IEC 61000-4-3 80MHz to 2.5GHz...
  • Page 40: Guidance And Manufacturer's Declaration - Electromagnetic Immunity

    40 SLIT LAMP HS-5000 5X------------------- ---------------------------------------------------------------- 11.6. Guidance and manufacturer’s declaration – electromagnetic immunity The EUT is intended for use in the electromagnetic environment specified below. The customer or the user of the EUT should assure that it is used in such an electromagnetic environment.
  • Page 41 -------------------------------------------------------------------------------------SLIT LAMP HS-5000 5X 41 NOTE 1) These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection from structures, objects and people. NOTE 2) It is essential that the actual shielding effectiveness and filter attenuation of the shielded location be verified to assure that they meet the minimum specification.
  • Page 42: Electric Diagram

    42 SLIT LAMP HS-5000 5X------------------- ---------------------------------------------------------------- 12. Electric Diagram...
  • Page 43: Technical Specifications

    -------------------------------------------------------------------------------------SLIT LAMP HS-5000 5X 43 13. Technical Specifications MICROSCOPE - HS-5000 5X 5x Type Galileian converging binocular Magnification 5 positions rotation drum Eyepiece 12.5x Total magnification 6x, 10x, 16x, 25x, 40x Real field of view 38.5, 22.2, 15.2, 10.5, 6.7 mm...
  • Page 44 44 SLIT LAMP HS-5000 5X------------------- ---------------------------------------------------------------- BASE Vertical Movement Min. 28mm Longitudinal Movement Min. 78mm. Lateral Movement Min. 98mm Fine base Movement Min. 10mm Power supply 100~240 V AC 50/60HZ 2.0A Power consumption 70VA Instrument Voltage 12V DC Halogem Projection...
  • Page 45: Service Information

    Dealer Phone No. : Model No.: Serial No.: If you can’t contact with your local distributor, you can directly get in touch with the service department of the HUVITZ using the phone number and the address written in the below table.
  • Page 46 46 SLIT LAMP HS-5000 5X------------------- ---------------------------------------------------------------- How to Contact HUVITZ Co., Ltd Write us at: Tel: +82-31-442-8868 HUVITZ Co., Ltd. Fax: +82-31-442-8619 Huvitz B/D, 689-3 Geumjeong-dong URL:http://www.huvitz.com Gunpo-si Gyeonggi-do, South Korea e-mail: hs-support@huvitz.com 435-862...