Advertisement

Quick Links

4Seasons Premium
40011600-1540 4Seasons Premium EN

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 4Seasons Premium and is the answer not in the manual?

Questions and answers

Summary of Contents for Faber 4Seasons Premium

  • Page 1 4Seasons Premium 40011600-1540 4Seasons Premium EN...
  • Page 2 I n s t a l l a t i o n I n s t r u c t i o n s 300 mm Ø 100 mm A C G...
  • Page 3 I n s t a l l a t i o n I n s t r u c t i o n s P2(-) P1(+) 0,5 M MAX.
  • Page 4 I n s t a l l a t i o n I n s t r u c t i o n s P1(+) P2(-)
  • Page 5 I n s t a l l a t i o n I n s t r u c t i o n s A = Min. 45 mm B = 25 mm Max. 100 mm C = 200 mm P2(-) P1(+)
  • Page 6 I n s t a l l a t i o n I n s t r u c t i o n s...
  • Page 7 1 Dear User Introduction Only have the appliance installed by a qualified installer according Congratulations on your purchase of a Faber fire! A quality product to the gas safety regulations. from which you will experience warmth and ambience for many Read this installation manual properly.
  • Page 8: Safety Instructions

    The 4Seasons Premium is provided with an electronic control system, which can compensate for the under pressure in a The 4Seasons Premium is a gas fire belonging to the category B22. mechanically ventilated house to an under pressure of 15Pa.
  • Page 9: Installation Requirements

    For the supply of combustion air and the discharge of combustion flue gas fan gasses, you must always use the Faber recommended discharge materials and flue gas fan from Exodraft (Inaterm) type For connecting the flue gas fan, use at least a RSV20041.
  • Page 10: Preparation And Installation Instructions

    Discharge Remove the door and frame to prevent damage. (fig. 1.2 and fig. 1.4) To ensure correct installation, Faber’s range of products includes a Make sure that the front of the installation box is flush with suitable chimney unit including a fan silencer. This unit can be the finished wall (dotted line F fig.1.2).
  • Page 11 Evaluate the flame spread by letting the fireplace work on Now turn off the service mode switch. both wide and high flame settings. See also user’s manual ITC 4Seasons Premium TIP: You can move around some of the decorative material to obtain the best flame spread.
  • Page 12: Annual Maintenance

    I n s t a l l a t i o n I n s t r u c t i o n s 7 Annual maintenance 5.2.4 Always check the flame effect with the door closed! Close the door, let the fireplace burn on a wide and high flame Checking and cleaning setting for 20 minutes and evaluate the flame effect.
  • Page 13: Technical Data

    I n s t a l l a t i o n I n s t r u c t i o n s 8 Technical data...
  • Page 14 202 Int. DETAIL A SCALE 1 : 5 1193 792 Ext. 640 Int. 749 Int. Dimensional Drawing 4Seasons Premium Controls Installation box Glen Dimplex Benelux BV P.O.box 219, NL-8440 AE Heerenveen Tel.:+31(0)513 656500 Fax:+31(0)513 656531 1/2"gas connection Builder opening Pressure pipes...
  • Page 15 I n s t a l l a t i o n I n s t r u c t i o n s...
  • Page 16 Dealerinfo: www.faber.nl info@faber.nl Saturnus 8 NL - 8448 CC Heerenveen Postbus 219 NL - 8440 AE Heerenveen...

Table of Contents