Retrofit Installation For Use With Existing Fluorescent Box Signs
1. Remove Existing Fluorescent Tubes
• Make sure power is off. Have a licensed electrician disconnect and remove all ballasts.
• Remove existing fluorescent tubes, leaving fluorescent lamp holders in place.
• Installers should disconnect lamp holder leads and make new connections from the LED driver directly to the LED
lamps. Lamp holders are to be used only for the purpose of holding the LED lamps in place.
• (Existing Signs Only) If removal of the existing lighting equipment eliminates the disconnect switch, as required by
applicable local, state, or country electrical codes; a new disconnect switch must be installed.
• (Existing Signs Only) Make sure the removal of lighting equipment does not compromise the integrity of the sign body
(i.e. water intrusion). Fill in all holes 0.5 in. (13 mm) or smaller with the appropriate amount of rated caulk or sealant.
For holes greater than 0.5 in. (13 mm), use an aluminum or zinc coated steel patch with rivets and sealant.
3. Insert Light bars into lamp-sockets
5. Unused wire ports should be capped with Watertight
End Cap provided in box, or use another extension cable
to tie the port back to the power supply.
This sign
has been
modified
to operate
LED lamps.
Do not
attempt
to install
8. This sign has been modified to operate LED lamps. Do not attempt to
or operate
fluorescent
install or operate fluorescent lamps in this sign. The marking for item
lamps in
shall have a minimum letter height of 2.4 mm (3/32 in) and shall be in
this sign.
Universal Bold, Arial Bold, Helvetica Bold, or Zurich BT Bold or equivalent
font. Markings in this image shall be provided verbatim.
5
6. Mount power supply
• Identify input and output secondary wires. Connect the power unit to the supply
in accordance with the applicable local, state, and country electrical codes, and the
instructions found in the power supply installation guide. All power supplies must be
installed in a raceway or suitable electrical enclosure.
• If required, the disconnect switch shall be installed by qualified personnel, in
accordance with applicable local, state, and country electrical codes.
• Spacing between LED power supplies shall be at least 25.4 mm (1 in) from end to end
and 101.6 mm (4 in) from side to side, in accordance with UL 48 Par. 4.2.3.2.3.1
2. Connect all light bar pieces, if necessary.
Install Retrofit Connectors on each side of light bar.
4. Connections: Wire the Concorde Bar II with male and female connectors to make longer
cascade. (see Cascading Information Guidelines on page 7 to see how many bars can
be run in a series)
7. Connect to power supply: Connect the white output
wire to the red Concorde cable wire and the black
output wire to the black cable wire. Connect female
cable end to male end coming off of Concorde Bar II and
tighten collar.

Advertisement