Periodic Maintenance; Sieve Maintenance; Festo Valve Island Maintenance - Nordson AZO E360 Customer Product Manual

Rotary sieve + hopper
Table of Contents

Advertisement

Periodic Maintenance

Component
Compressed Air System
Electrical System
System Grounds
Air Tubing

Sieve Maintenance

Festo Valve Island Maintenance

E 2018 Nordson Corporation
Note:
You may need to perform these procedures more or less often,
depending on your application requirements.
Open the drop leg and use a clean, white cloth to check for
Correct any problems immediately. Drain the air filters and change the
elements as necessary.
Tighten all electrical connections and inspect tor loose or broken wires. Check
the electrical system tor electrical safety every 12 months. The system must
comply with all local, state, and federal codes.
Check all equipment grounds. Electrical equipment must be grounded
according to the relevant code. For maximum transfer efficiency and safety,
electrostatic equipment must be grounded to provide a complete circuit from
the product, through the hangers, conveyors booth and back to the gun
controllers.
Refer to Grounding in the Safety section of this manual and to publication
number TCTT- 06- 3881 on the Nordson emanuals website
(http://emanuals.nordson.com/finishing) for more information on powder
coating system grounding.
Pressurise the system and identify if there any air leaks. Replace or repair any
damaged fittings or tubing.
Refer to the AZO Rotary Sieve manual for more information on sieve
maintenance. Available upon request from Nordson.
Manual: Valve terminals MPA- S (Typ32)
https://www.festo.com/cat/de_de/data/doc_engb/PDF/EN/TYP32_EN.PDF
Maintenance Procedure
21
contaminants.