Pass-through cable sleeves
Table of Contents

Advertisement

1. Open the device by depressing end buttons on pins while pulling pins out (see Fig. 1).
2. Fully open device by pivoting clamp bar assembly away from housing and attach
device to cable (see Fig. 2).
3. Close the device by pivoting cams onto the cable, making sure the "UP" arrow is
pointing up (see Fig. 3).
4. Reinstall pins through housing, ensuring that the ball detent passes completely
through housing assembly (see Fig. 4).
5. After cable sleeve is installed on lifeline, check security pins by trying to remove
the pins without depressing the buttons.
6. Test the cable sleeve for functionability of movement by working cams back and forth
and by running the device up and down on the lifeline.
7. Test the cable sleeve locking mechanism by pulling down sharply on the eye attach-
ment. Cable sleeve should lock onto cable.
Fig. 1
Fig. 3
To remove the Vi-Go Manual Cable Sleeve from the cable:
1. Depress end buttons on pins while pulling pins out.
2. Open the device by pivoting clamp bar assembly away from housing and remove
from cable.
netzerotools.com
Us er Ins truc tion s - En gli s h
10
netzerotools.com
Fig. 2
Fig. 4