Cheat Sheet-Winch 50; Before Use; Dmx Channels; Getting Started - Wahlberg 245 Winch 50 User Manual

Table of Contents

Advertisement

Cheat sheet-Winch 50

Before use

When using the Winch 50, always have a counter weight placed in the
wire loop. (Minimum 5 kg)
When using the Winch 50, make sure you can see it, so you have visual
confirmation on the movements.
The Winch 50 uses 6 DMX channels, in order to make it easier to learn how to use it.
Patch out the 6 DMX channels to faders on your lighting desk.

DMX channels

DMX channel 1 – Position.
DMX channel 2 – Position fine.
DMX channel 3 – Maximum speed
DMX channel 4 – Motor Enable – between 50 % and 55 %, to enable the motor output.
DMX channel 5 – Reset UP
DMX channel 6 – Manual DWN (Set range)

Getting started

1. Hang up the winch, so there is space for the wire to move without hitting the floor.
2. Put counterweight on the wire loop, minimum 5kg.
3. Connect to 230VAC –
4. Set DMX channel 4 between 50 % and 55 %. -
5. Set DMX channel 5 to 50% wait for the load to move to the top position. (There is a 3s
delay on this channel)
When it is at the top position set channel 5 to 0%
6. Set DMX channel 6 to 50 % wait for the wire loop to go 2m down (There is a 3s delay on
this channel)
When the hook is 2m out, set DMX channel 6 back to 0 % -
from the winch chassis and 2m
7. Set DMX channel 1 to 100 % and DMX channel 3 to 20 % -
to the top with 20 % speed.
8. Set DMX channel 1 to 50% and DMX channel 3 to 50 % -
1m down with 50 % speed.

Emergency stop switch (Only in versions with emergency stop!)

The emergency stop switch is connected to the female 4 pin XLR connector.
Pin 1 and Pin 2 should be connected to each other; otherwise the motor will not run.
Pin out:
Pin 1 = GND
Pin 2 = NC
Pin 3 = NC
Pin 4 = 12 – 15 volt DC
805.245.005
Date: January 10, 2017
14
(16 bit DMX channel)
(16 bit DMX channel)
The display is now showing the start-up message.
down.
Emergency stop input
Emergency stop input
Jaegergårdsgade 152/05A
DK-8000 Aarhus C
DENMARK
WWW.WAHLBERG.DK
Motor is now enabled.
Now the travel range is
The wire loop is now running
The wire loop is now running