Thewaterleveldatum(WLD)inthisexample:34 .76-24 .9+7 .65=>17 .51m
Thefollowingfigures/numbersfortheborearerequiredasentriestothedata
basetoachieveavalidcalculationofthewaterleveldatum .
Sensor depth from top of bore
1 . Sensordepthfromthetopofthebore=totalcablelength–10cm .
2 . "Totalcablelength"isprintedonalabelnearthecableconnector
(example:cablelength=11 .86m) .
3 . Togetthesensordepthinrelationtothetopofthebore,youmustsub-
tract10cmduetothecableconnectorlength(11 .86-0 .1=11 .76m) .
4 . Thisisalsothesensordepththatyouuseincalculationsandwriteintothe
Chatterdatabase(writtentotheserverfromtheChatterLink"Modbus"
tabinthefield"Sensordepth") .
EN 6.10 Chatter Hardware Manual 1511