Download Print this page
Emerson SAPAG CLASAR Series Technical Description, Installation, Operating And Maintenance Instructions
Emerson SAPAG CLASAR Series Technical Description, Installation, Operating And Maintenance Instructions

Emerson SAPAG CLASAR Series Technical Description, Installation, Operating And Maintenance Instructions

Check valves

Advertisement

Quick Links

SAPAG
www.valves.emerson.com
Check valves CLASAR®
Installation, operating and maintenance instructions
1. General instructions
1.1 General functioning
CLASAR check valve shutters move axially and valves can operate in any position, e.g. horizontal
flow, upward and downward flows.
1.2 Description
There are three types of CLASAR check valves:
• CLASAR type I for wafer-mounting between flanges DN 150
• CLASAR type II for wafer-mounting between flanges from DN 200 to DN 500
• CLASAR type Ill complete with flanges for DN > 600
Type 2
Type 1
Open
Closed
Parts list
Rep
Designation
1
Body
2
Obturator
3
Spring
4
O-Ring
5
Counter flange
CLASAR valves components
• Body
• Counter flange or rear shell
• Shutter
• Spring
Note: CLASAR valves are delivered without flange or support seals or tie-rods or bolts to secure
valves to pipework.
As for most valves and fittings, sliding flanges or similar on the pipework are recommended
to provide the clearances needed to insert and remove the valve and to prevent unacceptable
stressing due to inevitable misalignment.
At least one of the pipes connected to the valve must be firmly anchored to withstand the thrust
occurring on valve closure.
Emerson reserves the right to change the contents without notice
Type 3
Open
Closed
SAHSB-0020-EN-1306
Open
Closed

Advertisement

loading

Summary of Contents for Emerson SAPAG CLASAR Series

  • Page 1 At least one of the pipes connected to the valve must be firmly anchored to withstand the thrust occurring on valve closure. www.valves.emerson.com Emerson reserves the right to change the contents without notice SAHSB-0020-EN-1306...
  • Page 2 • Pressing by hand, fit the counterflange to the valve body (type I and II CLASAR). • Alternatively, bolt the rear shell into position (type Ill CLASAR with flanges). Emerson reserves the right to change the contents without notice page 2...
  • Page 3 S = welding neck or slip-on flanges F = flat flanges Torque Max. torque for thru-bolting (Nm) - non oxidized new bolting ø Max. torque Quality class 1300 Emerson reserves the right to change the contents without notice page 3...
  • Page 4 CLASAR pipe mounting - Force pump CLASAR Check valve Isolation valve concentric design Pump Pump CLASAR Check valve Isolation valve concentric design CLASAR Check valve CLASAR Check valve Pump Pump Emerson reserves the right to change the contents without notice page 4...
  • Page 5 Installation, operating and maintenance instructions CLASAR pipe mounting - In line mounting Isolation valve concentric design CLASAR Check valve CLASAR Check valve Isolation valve concentric design CLASAR Check valve CLASAR Check valve Emerson reserves the right to change the contents without notice page 5...