Error Codes; Rectify Error - Sony STR-DG500 Operating Instructions Manual

Hi-fi receivers: multi channel av receiver
Hide thumbs Also See for STR-DG500:
Table of Contents

Advertisement

The table below shows the display when
measurement starts.
Measurement for
Environment noise level
Speaker connection
Speaker level
Speaker distance
* The corresponding speaker indicator lights up in
the display during measurement.
When measurement ends, "COMPLETE"
appears on the display and the settings are
registered.
Notes
• Auto Calibration cannot detect the sub woofer.
Therefore, all sub woofer settings will be
maintained.
• You cannot select Auto Calibration when
headphone is connected.
• The measurement process will take a few minutes
to complete.
Tips
• When Auto Calibration starts:
– Stand some distance from the speakers and the
listening position to avoid measurement failure.
This is because test signals are output from the
speakers during measurement.
– Avoid making noise to get a more accurate
measurement.
• The Auto Calibration function will be canceled
when you do the following during the
measurement process:
– Press ?/1, input buttons or MUTING.
– Change the volume level.
– Press AUTO CAL again.
28
GB
Display
NOISE.CHK
MEASURE and SP
DET. appears
alternately*
MEASURE and
GAIN appears
alternately*
MEASURE and
DISTANCE appears
alternately*
Error and warning codes

Error codes

When an error is detected during Auto
Calibration, an error code will appear on the
display cyclically after each measurement
process as follows:
Error code t blank display t (error code t
a)
t PUSH t blank display
blank display)
t ENTER
a)
Appears when there are more than one error code.
To rectify the error
1
Record down the error code.
2
Press the control button.
3
Press ?/1 to turn off the receiver.
4
Rectify the error.
For details, see "Error code and remedies"
below.
5
Turn on the receiver and perform Auto
Calibration again (page 27).
Error code and remedies
Error
Explanation
code
ERROR 10 The environment
is too noisy.
ERROR 11 The speakers are
placed too near
the optimizer
microphone.
ERROR 20 Front speakers
are not detected
or only one front
speaker is
detected.
ERROR 21 Only one
surround speaker
is detected.
ERROR 23 Surround back
speaker is
detected but
surround
speakers are not
connected.
Remedies
Make sure the
environment is
quiet during Auto
Calibration.
Place your speakers
further away from
the optimizer
microphone.
Check the front
speaker
connection.
Check the surround
speaker
connection.
Be sure to connect
the surround
speakers.