Vent-Axia HR300RW6 Operating, Installation And Servicing Instructions
Vent-Axia HR300RW6 Operating, Installation And Servicing Instructions

Vent-Axia HR300RW6 Operating, Installation And Servicing Instructions

Semi-remote wall mounted heat recovery ventilator

Advertisement

Quick Links

HR300RW6
Semi-Remote Wall Mounted
Heat Recovery Ventilator
Installation and
Servicing Instructions
Please leave these instructions with the user

Advertisement

loading
Need help?

Need help?

Do you have a question about the HR300RW6 and is the answer not in the manual?

Questions and answers

Summary of Contents for Vent-Axia HR300RW6

  • Page 1 Please leave these instructions with the user HR300RW6 Semi-Remote Wall Mounted Heat Recovery Ventilator Installation and Servicing Instructions...
  • Page 3: Table Of Contents

    Contents Section Page Introduction Site Requirements Installation Electrical Maintenance...
  • Page 4: Introduction

    70% heat recovery from the stale extracted air. Bezel Fig. 1 Ancillary Equipment 1. The HR300RW6 unit can be used in conjunction with a range of ancillary equipment. Controller: A range of controllers - see section Fresh Air 3.1 Controllers.
  • Page 5: Site Requirements

    2.0 Site Requirement Information 1. The unit is designed for installation in external walls with a thickness of between 150mm to 315mm. 2. The unit must be sited and connected by a suitably qualified person and be in accordance with current UK Building Regulations and I.E.E. Wiring Regulations (BS 7671).
  • Page 6: Installation

    3.0 Installation Controllers 1. The HR300RW6 unit can be installed in conjunction with a number of controllers. VCON6: The VCON6 controller can be used to provide Off/Low/Normal/Boost/Sensor control. (The HS6 humidistat or TIM2 over-run timer can be used in conjunction with the VCON6 controller to provide automatic control.
  • Page 7 From Inside Blind Grommet 1. Slide the unit into the mounting hole and ensure that the minimum overhang requirements are achieved inside and out (Fig. 5). 2. The HR300RW6 requires an overhang internal 380mm and external (Fig. 6): Internal 50mm...
  • Page 8: Electrical

    4.0 Electrical Electrical Connections 230V 50Hz 100W max 1. Wiring must be via a 3A fused switched spur with a 3mm contact separation in each pole. The wiring should be suitably (Basec or Har) approved cable of appropriate current carrying capacity.
  • Page 9: Maintenance

    5.0 Maintenance Cleaning the Unit 1. To ensure optimum performance, the unit should be inspected every 6 months for build up of dust or debri and washed every 12 months or at periods determined by the level of contamination experienced and according to the following procedure.
  • Page 10 6.0 Notes...
  • Page 12 Comp N 372561 - Iss B 0405 Vent-Axia Ltd Fleming Way Crawley West Sussex RH10 9YX www.vent-axia.com...