Composite pressurised water tanks

Advertisement

Quick Links

Pentair Australia / New Zealand
Distributed in NZ By:
PH: 1-800 664 266 (AuSTRALIA), 0800 664 269 (NEW ZEALAND)
© 2013 Pentair, Ltd. All Rights Reserved.
Composite Pressuri ed Water Tanks
®
APSC Series
Freephone 0508 634 34 1
7 Monier Pl, Mt Wellington, Auckland 1060, New Zealand
OWNER'S MANUAL
5894 0112
CH21087 (02/11/13)

Advertisement

Table of Contents
loading

Summary of Contents for Pentair Pro-Source APSC Series

  • Page 1 APSC Series 5894 0112 Distributed in NZ By: Freephone 0508 634 34 1 7 Monier Pl, Mt Wellington, Auckland 1060, New Zealand PH: 1-800 664 266 (AuSTRALIA), 0800 664 269 (NEW ZEALAND) CH21087 (02/11/13) © 2013 Pentair, Ltd. All Rights Reserved.
  • Page 2: Important Safety Instructions

    Safety • Product Specifications Important Safety Instructions 2. Always test water from well for purity before using. Check your local health department for SAVE THESE INSTRUCTIONS - This manual contains testing procedure. important instructions that should be followed during 3. Before installing or servicing your tank, BE SURE installation, operation, and maintenance of the product.
  • Page 3: Warranty

    Warranty Pentair Water warrants that, when this product is used for the purpose it Spare Parts: was designed, is correctly housed and vented against weather, vermin, Spare parts are usually stocked for a reasonable period of time dust etc., that it will be free of material and manufacturing defects at following last production.
  • Page 4: Safety • Installation

    Safety • Installation Operating Cycle Check pressure frequently with an accurate tire pressure gauge until correct pressure has been reached. For 1. Tank nearly empty – air expands filling area inside correct pre-charge pressure settings, see Table 1. air cell (Figure 2A). 2.
  • Page 5: Installation

    Installation • Operation Proceed as follows: Water Yield Per Pump Cycle 1. Open faucets furthest from tank and allow pump Liters (U.S. Gallons) to operate. Tank Capacity Pressure Switch Setting Model Number Liters (U.S. Gallons) kPa (psig) 2. Air in the system will cause a sputtering flow; allow faucets to run until you have a steady, air free stream.
  • Page 6: Operation

    Operation Check Pump Pressure Switch Setting B. Reconnect power supply to pump and pump up pressure in system. 1. To check pressure switch setting, disconnect power C. Disconnect power supply to pump again and to pump at supply panel (but be sure to leave re-check switch setting.
  • Page 7: Maintenance

    Maintenance Air Cell Replacement 13. While squeezing the air cell, push the valve end of the air cell into the bottom of the tank. Push it in as HAZARDOuS PRESSuRE. Read owner’s far as possible without losing the bottom of the air manual before attempting to install, operate, or service cell in the tank.
  • Page 8: Repair Parts

    Repair Parts Ref. Description Qty. Part Number Polar Boss Cap Kit (includes Ref. Nos. 1, 2, 3, 4, 5, 6) Pole Piece Cap Valve Stem Nut Washer CH20294K C-Clip Polar Boss Cap O-Ring Base See table below Elbow Adapter Kit (includes Ref. Nos. 8, 9, 10) O-Ring Adapter Lid See table below...