19" LCD Color Monitor
No Picture
Check the signal cable
Measure U703 PIN2=3.3V
U701 PIN2=1.8V
Measure X401 oscillate
waveform is normal
Check HS/VS from CN405
is normal
No picture
OK
OK
OK
OK
Replace U401
NG
Change the signal cable
NG
Replace U701, U703
NG
Replace X401
NG
Check Correspondent
component
33