INSTALLATION AND OPERATION MANUAL, ELECTRIC MODULAR SKILLETS,
9.0 TROUBLESHOOTING
BRAISING PAN
HEATING ELEMENTS DO NOT COME ON:
1. Power supply not "ON".
2. Pan not in down position.
3. Defective limit switch.
4. Defective thermostat.
5. Defective elements or loose terminals.
6. Defective contactors.
BRAISING PAN WILL NOT OPERATE (UP OR DOWN):
1. Power supply not "ON".
2. Defective UP/DOWN switch.
3. SEE TROUBLESHOOTING - HYDRAULICS (below).
TROUBLESHOOTING - HYDRAULICS
1. DIRTY OIL:
1)
Components not properly cleaned after servicing.
2)
Inadequate screening in fill pipe.
3)
Air breather left off.
4)
Filter dirty or ruptured.
Part No. 10130R3
MODELS EMTS-30, EMTS-40
, EMTS-60
15