Troubleshooting - Crown GC-12 Installation & Operation Manual

Gas fired steam jacketed tilting kettle
Hide thumbs Also See for GC-12:
Table of Contents

Advertisement

Gas Fired Steam Jacketed Tilting Kettle

Troubleshooting

PROBLEM
Unit does not come on
Unit is on electrically, but
does not heat
Unit is slow to preheat and
slow to recover
Contact the factory, the factory representative or a local service company to perform maintenance and repairs.
INSTALLATION & OPERATION MANUAL 10105 REV 0 (04/21)
PROBABLE CAUSE
Power switch and/or thermostat is "OFF".
Unit is not plugged in.
Main power supply is off.
Tilt micro switch out of alignment or faulty.
Gas supply to the unit is "OFF".
The manual shut-off valve is "OFF".
The thermostat is not turned "ON."
The kettle is not in the upright position.
The electronic ignition is not functioning.
Pressure switch is not functioning.
Low water in kettle jacket.
Thermostat is not functioning.
Wrong size orifices.
Wrong gas supply.
Incorrect pressure at supply.
Loss of vacuum.