Adhering/Replacing Sanding Paper; Setting The Sanding Table Angle; Using An Angle Stop; Connecting External Dust Extraction - Parkside PTSG 140 B2 Translation Of The Original Instructions

Table of Contents

Advertisement

Available languages

Available languages

G B
I E
N I
Mounting the sanding table:
3. To mount the sanding table (11), push
the sanding table holder (10) back onto
the device.
4. Insert the screw (9) with washer (8) and
tighten.
Ensure the 4 lugs are correctly
positioned (see illustration
otherwise screw (
in.
Adhering/replacing
sanding paper
Do NOT remove the white film
from the sanding disc!
Caution! Risk of injury! Discon-
nect the device from the power sup-
ply to prevent unintentional starting.
dismount the sanding table (11)
and holder (10) (see "Dismounting/
mounting the sanding table").
1
verse side of the sanding paper (18).
When re-using it, remove the sanding
1
2. Stick the sanding paper (18) centrally
onto the sanding disc (1) while ensuring
there are no bubbles.
Trial run:
Perform a trial run at top speed without a
load for at least 1 minute whenever you
change the sanding paper. Remain outside
the hazard area while doing so.
The sanding paper (18) can be
re-used provided you stick it onto
1 0
)
9) will not screw
-
1
provided when being stored.
Setting the sanding
table angle
The angle of the sanding table (11) can be ad-
justed continuously between -10° and +50°.
1. Release the screws (7).
2. Set the desired angle using the angle
scale (6).
3. Tighten the screws (7).

Using an angle stop

1. Release the angle stop screw (13b) and
set the desired angle using the scale
onto the rail marking (13a).
2. Fix the angle stop (13) in place by tigh-
tening the screw (13b).
3. Slide the rail of the angle stop (13a) into
the slot (12) on the sanding table (11).
Connecting external
dust extraction
Please check the operating manual
of your vacuum cleaner to ascertain
whether it is suitable for the suction
of grinding chips.
Connecting external dust extrac-
tion:
1. Place the angle adapter (14) into the
opening on the device.
Ensure that you slide the lug on the
angle adapter (14) into one of the two
slots in the device opening (see de-
tailed illustrations).
2. Rotate the angle adapter (14) into a
vertical or horizontal position to secure
the angle adapter (14) against falling
out.
1

Hide quick links:

Advertisement

Chapters

Table of Contents
loading