Door Open: Time
Sets the length of time the door remains open before the machine initiates a
013*
call.
This setting is enabled only when SP5508 004 is set to 1.
SC/Alarm Setting
With @Remote in use, these SP codes can be set to issue an SC call when an
5515
SC error occurs. If this SP is switched off, the SC call is not issued when an
SC error occurs.
001 SC Call
002 Service Parts Near End
003 Service Parts End
004 User Call
006 Communication Test
007 Machine Information
008 Alarm Notice
010 Supply Automatic Order
011 Supply Management Report
012 Jam/Door Open Call
[Memory Clear]
5801
Before executing any of these SP codes, print an SMC Report.
All Clear
001
Initializes items SP5801-002 to -014 below.
Turn the main power switch off and on after executing this SP.
SM Appendix
[ 03 to 30 / 10 / 1 minute/step]
CTL
-
[0 or 1 / 1 / -]
0: Off, 1: On
[0 or 1 / 0 / -] 0: Off,1: On
[0 or 1 / 1 / -] 0: Off,1: On
3-39
System Service Mode