User guide,
Error messages
12
cont.
An overview of possible errors which prevent normal operation
Error message
Yellow light on
centre LED with
emptying symbol
and FULL on display
Red light on right
warning LED HIGH
TEMP on display
Red light on right
warning LED AMBI-
ENT TEMP on
display
Red light on right
warning LED SEN-
SOR FAIL on
display. One of the
internal sensors is
defective. Use the
+/- keys to toggle
between 3 possible
errors
Red light on right
warning LED LP
STOP on display
Illustration
Cause
Water container full
Pressure or tem-
perature in high
pressure element
too high
Room temperature
out of normal range
1: EVAP FAIL
Evaporator
thermometer
defective
2: COND FAIL
Condenser
thermometer
defective
3: ROOM FAIL The
internal room
thermometer is
defective
Leak in cooling
circuit
Remedy
See guide below for emptying
Check filter and dehumidifier
for dirt in airways
Place the dehumidifier in the
specified temperature range,
between 3°-32°C
SENSOR FAIL
Requires an authorised ser-
vice technician
Requires an authorised ser-
vice technician
Requires an authorised ser-
vice technician
Requires an authorised ser-
vice technician
Continued on next page